2020
DOI: 10.1016/j.diamond.2020.107747
|View full text |Cite
|
Sign up to set email alerts
|

A novel carbon paste electrode modified by NP-Al2O3 for the electrochemical simultaneous detection of Pb (II) and Hg (II)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
10
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 36 publications
(11 citation statements)
references
References 41 publications
1
10
0
Order By: Relevance
“…The increase in peak currents from 0.3253 mA·cm −2 (with CPE) to 0.4681 mA·cm −2 (with CPE-ACC) not only shows that the CPE-type electrode has indeed been modified but also that the modification boosts the recognition of lead. Previous work has shown similar behavior [ 19 , 20 ].…”
Section: Resultssupporting
confidence: 63%
“…The increase in peak currents from 0.3253 mA·cm −2 (with CPE) to 0.4681 mA·cm −2 (with CPE-ACC) not only shows that the CPE-type electrode has indeed been modified but also that the modification boosts the recognition of lead. Previous work has shown similar behavior [ 19 , 20 ].…”
Section: Resultssupporting
confidence: 63%
“…[11,12] To improve the sensor figures of merit, many examples of carbon paste electrodes modified with adsorbing materials appeared in the dedicated literature. [13][14][15] Inorganic insulating modifiers (SiO 2 , Al 2 O 3 , etc.) are particularly appealing as they are usually characterized by high chemical stability and large surface area.…”
Section: Introductionmentioning
confidence: 99%
“…In parallel, the research opened the way to non metallic, carbonaceous materials encompassing a large amount of studies on the so‐called carbon paste electrodes due to their easy fabrication and their easy tailoring with proper modifiers [11,12] . To improve the sensor figures of merit, many examples of carbon paste electrodes modified with adsorbing materials appeared in the dedicated literature [13–15] . Inorganic insulating modifiers (SiO 2 , Al 2 O 3 , etc.)…”
Section: Introductionmentioning
confidence: 99%
“…8 Alternatively, the electro-analytical technique has been widely applied owing to its low cost and exposure range either in part per billion (ppb) or trillion (ppt) in a few cases. [9][10][11] Presently, most researchers focus on detecting heavy metal ions by anodic stripping voltammetry because it is a rapid and insightful electro-analytical method, which is also used to analyze an effective pre-concentration and consequent measurements step. [12][13][14] Nevertheless, graphite electrodes usually show limited sensitivity due to their low precise surface area, inadequate electro active centers, and low adsorption capability for ions.…”
Section: Introductionmentioning
confidence: 99%