2016
DOI: 10.1016/j.bios.2016.01.064
|View full text |Cite
|
Sign up to set email alerts
|

A novel biosensor based on competitive SERS immunoassay and magnetic separation for accurate and sensitive detection of chloramphenicol

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
38
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 110 publications
(39 citation statements)
references
References 48 publications
0
38
0
1
Order By: Relevance
“…To use SERS to detect binding events, we conjugate one affinity reagent to gold nanoparticles (AuNPs) and the other to a gold metal film. The AuNP-Au film sandwich structure formed in the presence of the target molecule becomes a SERS hot spot, generating a strong and unambiguous signal that indicates a true positive (10). One can analyze the SERS signals by using the traditional "analog" method to correlate the intensity of one Raman reporter to the known protein concentration, thereby developing an intensity vs. concentration calibration curve (5,6,10,11).…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…To use SERS to detect binding events, we conjugate one affinity reagent to gold nanoparticles (AuNPs) and the other to a gold metal film. The AuNP-Au film sandwich structure formed in the presence of the target molecule becomes a SERS hot spot, generating a strong and unambiguous signal that indicates a true positive (10). One can analyze the SERS signals by using the traditional "analog" method to correlate the intensity of one Raman reporter to the known protein concentration, thereby developing an intensity vs. concentration calibration curve (5,6,10,11).…”
mentioning
confidence: 99%
“…The AuNP-Au film sandwich structure formed in the presence of the target molecule becomes a SERS hot spot, generating a strong and unambiguous signal that indicates a true positive (10). One can analyze the SERS signals by using the traditional "analog" method to correlate the intensity of one Raman reporter to the known protein concentration, thereby developing an intensity vs. concentration calibration curve (5,6,10,11). In contrast, we have opted for an improved "digital" method, in which many SERS spectra are collected in a predetermined area of the gold surface under computer control, after which true positives can be identified by using a classical least-squares (CLS) approach to measure the number of sites that report significant contributions from both reporters.…”
mentioning
confidence: 99%
“…Functionalized magnetic beads are widely used in LFA (Hwang et al, 2016;Tang et al, 2009), and LFAs based on magnetic separation provide several advantages, such as easy separation, short analytical times, and wide linear ranges (Yang, Hu, & Dong, 2016). In Liu's work (Liu et al, 2015), a two-step LFA based on immunomagnetic beads was developed to detect trace Aflatoxin M 1 in milk.…”
Section: Introductionmentioning
confidence: 99%
“…Magnetic properties have been widely utilized as a component of complex nanostructures in multifunctional SERS active NPs [18,19,20,21]. They are usually exploited for the separation of cells [22] or small molecules [23] because NP movement is easily controlled by applying an external magnetic field.…”
Section: Introductionmentioning
confidence: 99%