2018 IEEE 9th Annual Information Technology, Electronics and Mobile Communication Conference (IEMCON) 2018
DOI: 10.1109/iemcon.2018.8615033
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Biomedical Technology Based on the Use of Artificial Muscles to Assist with Hand Functions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 21 publications
0
6
0
Order By: Relevance
“…Patiño et al [ 82 ] also developed a wearable orthosis for hand rehabilitation movements, with a TCP actuator on each finger (Figure 8b). The exoskeleton is composed of two main parts fitted to the dorsum of the hand and the fingers.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Patiño et al [ 82 ] also developed a wearable orthosis for hand rehabilitation movements, with a TCP actuator on each finger (Figure 8b). The exoskeleton is composed of two main parts fitted to the dorsum of the hand and the fingers.…”
Section: Discussionmentioning
confidence: 99%
“…However, some of the deficiencies in smart materials can be remedied through the SWRR design. Human Body [34] Skeletal Muscles 20 N/A 0.1 20 Maximum N/A Korea Institute of Machinery and Materials [101] Universidad Iberoamericana [82] (2018) TCP 10 5.4 1.1 %0.02 L: N/A D: 2.5 mm Bio-robotics and Smart Systems Laboratory [59] (2017) MENRVA Group [81] (2016) TCP 15. 0.9 N/A 0.1 N/A KAIST [97] Ajou University [92] (2020) SMA 5 10.5 594 %1 L: 800 mm D: 0.15 mm Carlos III University of Madrid [52] [89] (2009) SMA %3 10 203 %0.025 L: 2.5 m D: 0.25 mm Artificial Intelligence Laboratory [88] The required torque depends on two different aspects, the generated force and the lever arm.…”
Section: Artificial Muscles Enhancements Techniquesmentioning
confidence: 99%
“…A strategy to increase the response time could be to briefly apply a pulsed signal with high power peaks [12,26]. However, the continuation of a high-power pulse will produce an overheating of the actuator, causing it to break or burn out [27]. Hence, a control strategy should be applied to avoid overheating the actuator and work under safety actuation ranges.…”
Section: Displacement Control Implementationmentioning
confidence: 99%
“…Patiño et al [29] developed a wearable orthotic device for hand rehabilitation featuring individual TCP actuators for each finger. The orthosis consisted of two main components: one fitted to the dorsum of the hand and another for the fingers.…”
Section: Introductionmentioning
confidence: 99%