2006
DOI: 10.1016/j.snb.2005.07.025
|View full text |Cite
|
Sign up to set email alerts
|

A novel biochip technology for detection of explosives–TNT: Synthesis, characterisation and application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
36
0

Year Published

2007
2007
2016
2016

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 63 publications
(36 citation statements)
references
References 42 publications
0
36
0
Order By: Relevance
“…Also, TNT biosensor based on an anti-TNT antibody was reported using a displacement assay of the surface-confi ned antibody by the TNT, and readout of the detachment of the antibody by surface plasmon resonance (SPR) [ 16 , 17 ] or quartz crystal microbalance (QCM). [ 17 ] Also, the aggregation of donor-modifi ed Au nanoparticles in the presence of the TNT acceptor substrate was used for the optical detection of TNT. [ 18 ] Quantum dots were, similarly, applied for the development of TNT [ 19 ] or RDX [ 20 ] luminescence biosensors.…”
mentioning
confidence: 99%
“…Also, TNT biosensor based on an anti-TNT antibody was reported using a displacement assay of the surface-confi ned antibody by the TNT, and readout of the detachment of the antibody by surface plasmon resonance (SPR) [ 16 , 17 ] or quartz crystal microbalance (QCM). [ 17 ] Also, the aggregation of donor-modifi ed Au nanoparticles in the presence of the TNT acceptor substrate was used for the optical detection of TNT. [ 18 ] Quantum dots were, similarly, applied for the development of TNT [ 19 ] or RDX [ 20 ] luminescence biosensors.…”
mentioning
confidence: 99%
“…The silicalite MFI-type zeolite selective explosives absorber discussed above was grown on the end of an optical fiber, and the explosives were detected using changes in refractive index (or optical thickness) [67]. Tait and colleagues coated a fiber Bragg grating with polymer materials, and detected the expansion of the polymer when it adsorbs the target molecule via the changes in the Bragg grating period [150].…”
Section: Other Spectroscopic Methodsmentioning
confidence: 99%
“…Larsson and colleagues demonstrated a novel biochip for TNT detection using self-assembled monolayers (SAMs) of hydroxyl-terminated oligo(ethylene glycol)-thiols containing three different TNT analogues in different proportions and either surface plasmon resonance (SPR) or quartz crystal microbalance (QCM) transduction [67]. The detection limit was found to fall in the 1-10 ng/mL range in liquids, and the analysis times were 100-400 s. An alternative transduction scheme uses field effect transistors (FET) based on organic materials.…”
Section: Nanotechnologymentioning
confidence: 99%
“…(21) Oligo(ethylen glycol)-alkylthiols terminated with a hydroxyl group and a TNT analogue were synthesized and the sensor surface was modified with mixed SAMs using the synthesized chemicals. Their measurement procedure is different from our procedure.…”
Section: Comparison Of Two Measurement Proceduresmentioning
confidence: 99%