2021
DOI: 10.1016/j.cirpj.2021.03.001
|View full text |Cite
|
Sign up to set email alerts
|

A novel approach for a modular taper junction in hip stems using turn-milling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
9
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(10 citation statements)
references
References 14 publications
1
9
0
Order By: Relevance
“…Figure 5 b shows the maximal (1754 N) and minimal (1465 N) dismantling forces for the furrowing and rough machined taper junctions, respectively. This figure partly shows the double-sided influence of the microgroove pattern as observed and reported in Döbberthin et al [ 27 ] with somewhat similar assembly forces in [ 27 ] (4 kN) to those used in Mai et al [ 28 ]. In a study by Falkenberg et al [ 36 ], it was demonstrated that the presence of microgrooves (amplitude of 30 µm) did not produce any significant changes in the micromotions at the head–trunnion interface under various taper angle mismatches of 0.052°, 0.100°, and 0.134° and assembly forces of 2, 4, and 6 kN.…”
Section: Taper Junctions Of Hip Implantssupporting
confidence: 82%
See 4 more Smart Citations
“…Figure 5 b shows the maximal (1754 N) and minimal (1465 N) dismantling forces for the furrowing and rough machined taper junctions, respectively. This figure partly shows the double-sided influence of the microgroove pattern as observed and reported in Döbberthin et al [ 27 ] with somewhat similar assembly forces in [ 27 ] (4 kN) to those used in Mai et al [ 28 ]. In a study by Falkenberg et al [ 36 ], it was demonstrated that the presence of microgrooves (amplitude of 30 µm) did not produce any significant changes in the micromotions at the head–trunnion interface under various taper angle mismatches of 0.052°, 0.100°, and 0.134° and assembly forces of 2, 4, and 6 kN.…”
Section: Taper Junctions Of Hip Implantssupporting
confidence: 82%
“…The influence of the microgrooves can also be improved by manipulating the parameters of the microgroove creation procedure. In this regard, the twist-off strength of the turned taper junction was strongly improved by the turn milling method in Döbberthin et al [ 27 ]. It was shown that, as a function of the machining parameters such as the rotational speed and axial feed, the resulted topography on the trunnion surface (and, thus, its integrity) changes significantly ( Figure 3 a–c).…”
Section: Taper Junctions Of Hip Implantsmentioning
confidence: 99%
See 3 more Smart Citations