2007
DOI: 10.1063/1.2644697
|View full text |Cite
|
Sign up to set email alerts
|

A New XAFS Beamline NW10A at the Photon Factory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
45
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
8

Relationship

4
4

Authors

Journals

citations
Cited by 49 publications
(45 citation statements)
references
References 0 publications
0
45
0
Order By: Relevance
“…A Si(111) double-crystal monochromator was used to produce a monochromatic X-ray beam. The beam was focused into an area smaller than 1 mm × 1 mm (Nomura and Koyama, 1996). The monochromator was calibrated at Mn-K, Fe-K, and Zn-K edges, respectively, at 6539 eV, 7113 eV, and 9663 eV by the most intensive peak in the transmission signals from each metallic foil.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…A Si(111) double-crystal monochromator was used to produce a monochromatic X-ray beam. The beam was focused into an area smaller than 1 mm × 1 mm (Nomura and Koyama, 1996). The monochromator was calibrated at Mn-K, Fe-K, and Zn-K edges, respectively, at 6539 eV, 7113 eV, and 9663 eV by the most intensive peak in the transmission signals from each metallic foil.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…Elemental speciation for Mn, Fe, and Zn was performed using XANES spectroscopy at a beamline (BL-12C) of the Photon Factory in the Institute of Material Structure Science, High Energy Accelerator Research Organization (KEK-PF) (Nomura and Koyama, 1996;Ohta et al, 2004). The KEK-PF storage ring was operated at 2.5 GeV with a 450 mA maximum current.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Imaging XAFS measurement was carried out at the NW10A beamline, 5 the Photon Factory Advanced Ring (PF-AR), the High Energy Accelerator Research Organization (KEK). We used two kinds of measuring methods.…”
Section: Methodsmentioning
confidence: 99%
“…[39][40][41][42][43][44][45][46] Pt L 3 -edge XAFS spectra were measured at an X-ray beam line BL-12C of Photon Factory in Institute for Materials Structure Science, High Energy Accelerator Research Organization (KEK-IMSS-PF) using a Si(111) monochromator in the fluorescence mode. 47,48 XAFS measurement was performed in 200 ml/min gas flow. A 19-element SSD was used for the fluorescence detection.…”
Section: B Xafs Measurementsmentioning
confidence: 99%