A New Validated Potentiometric Method for Batch and Continuous Quality Control Monitoring of Oseltamivir Phosphate (Taminil) in Drug Formulations and Biological Fluids

Abstract: A new validated potentiometric method is described for batch and continuous quality control monitoring of the drug oseltamivir phosphate (Taminil) (OST). The method involves the development of a potentiometric sensor responsive to the drug based on the use of the ion‐association complex of (OST+) cation with phosphomolybdate anion (PMA−) as an electroactive material in a poly(vinyl chloride) matrix membrane plasticized with o‐nitrophenyloctyl ether (o‐NPOE). Optimization of the performance characteristics of t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 22 publications
0
8
0
Order By: Relevance
“…OSP was derivatized through the Hantzsch reaction of its primary amino group with acetylacetone and formaldehyde[ 45 ]. The calculated LOQ and LOD values were respectively 0.08 μg/mL and 0.24 μg/mL: these values were considerably lower than LLOQ (7.4 μg/mL) and LOD (3.73 μg/mL), obtained with the potentiometric method proposed by Hassan et al [ 44 ].…”
Section: Sample Pre-treatment and Extraction Of Covid-19 Antiviral Drmentioning
confidence: 62%
See 3 more Smart Citations
“…OSP was derivatized through the Hantzsch reaction of its primary amino group with acetylacetone and formaldehyde[ 45 ]. The calculated LOQ and LOD values were respectively 0.08 μg/mL and 0.24 μg/mL: these values were considerably lower than LLOQ (7.4 μg/mL) and LOD (3.73 μg/mL), obtained with the potentiometric method proposed by Hassan et al [ 44 ].…”
Section: Sample Pre-treatment and Extraction Of Covid-19 Antiviral Drmentioning
confidence: 62%
“…One of the major challenges when developing a method for the quantification of pharmaceutical compounds in bio-fluids and tissues is the practical issues related to acquiring large volumes of sample for the preparation of calibration standards and quality controls [ 42 ]. Although the calibration standards should be prepared in the same biological matrix as the one that is going to be analysed, by adding an internal standard as well [ 28 ], many methods for antiviral drugs’ quantification have been validated in aqueous solutions [ 20 , [43] , [44] , [45] , [46] , [47] , [48] , [49] ].…”
Section: Methods Validation In Pharmaceutical Analysis Of Covid-19 Antmentioning
confidence: 99%
See 2 more Smart Citations
“…The potentiometric output was measured with the data acquisition setup. A laboratory-made flow-through tubular potentiometric cell, equipped with CoPC-PVC membrane, was fabricated as previously described [48] and used in a single-channel flow injection system. The cell was assembled and incorporated in a flow injection analysis system.…”
Section: Equipmentmentioning
confidence: 99%