2014
DOI: 10.5155/eurjchem.5.2.241-246.1000
|View full text |Cite
|
Sign up to set email alerts
|

A new validated bio-analytical liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method for the quantification of Azithromycin in human plasma

Abstract: A simple, rapid and sensitive LC-MS/MS method was developed and validated for the quantification of azithromycin (AZI) in human plasma. Sildenafil citrate was used as an internal standard. The analytes were extracted from human plasma samples by liquid-liquid extraction technique. The reconstituted samples were chromatographed on a reversed -phase column C18, 50 × 2.1 mm, 5 µm from Waters, by using a 80:20 (v:v) mixture of acetonitrile and 0.1% formic acid in water as the mobile phase at a flow rate of 0.5 mL/… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 21 publications
0
2
0
Order By: Relevance
“…Spectrometric methods include UV-VIS spectrophotometric [9] and spectrofluorimetric methods [10], NMR spectroscopy [11] and electrospray tandem mass spectrometry [12]. Examples of HPLC and gas chromatography comprise: liquid chromatography-electrospray-mass spectrometry (MS) [13], ultra-performance liquid chromatography with tandem MS [14][15][16], HPLC coupled with electrochemical detection [17], HPLC with UV detector [18], rapid resolution reversed-phase HPLC with diode array detector [19] and gas chromatography coupled with MS [20].…”
Section: Introductionmentioning
confidence: 99%
“…Spectrometric methods include UV-VIS spectrophotometric [9] and spectrofluorimetric methods [10], NMR spectroscopy [11] and electrospray tandem mass spectrometry [12]. Examples of HPLC and gas chromatography comprise: liquid chromatography-electrospray-mass spectrometry (MS) [13], ultra-performance liquid chromatography with tandem MS [14][15][16], HPLC coupled with electrochemical detection [17], HPLC with UV detector [18], rapid resolution reversed-phase HPLC with diode array detector [19] and gas chromatography coupled with MS [20].…”
Section: Introductionmentioning
confidence: 99%
“…In a previous study, LLOQ was obtained at 0.1 ng/ml with a solid phase extraction method using UPLC-MS/MS, and 1.66 ng/ml of Cmax lercanidipine was obtained from healthy subjects [5]. The objective of this research is to obtain an optimum and validated method for analyzing lercanidipine in plasma using Ultra Performance Liquid Chromatography of Tandem Mass Spectrometry (UPLC-MS/MS).…”
Section: Introductionmentioning
confidence: 99%