2003
DOI: 10.1016/s0165-0270(03)00094-3
|View full text |Cite
|
Sign up to set email alerts
|

A new transparent multi-unit recording array system fabricated by in-house laboratory technology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2005
2005
2021
2021

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 9 publications
0
9
0
Order By: Relevance
“…Ganglion cell somas were sometimes visualized using Azure B (Sigma-Aldrich) solution, a few drops of which were added to the superfusate flowing over the retina at the beginning of recording. 30 Under these conditions, retinas can remain stably responsive for 8 or more hours.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Ganglion cell somas were sometimes visualized using Azure B (Sigma-Aldrich) solution, a few drops of which were added to the superfusate flowing over the retina at the beginning of recording. 30 Under these conditions, retinas can remain stably responsive for 8 or more hours.…”
Section: Methodsmentioning
confidence: 99%
“…Multi-electrode arrays allowed testing the effects of tACS current on neighboring ganglion cells simultaneously. The multi-electrode arrays were similar to those of Amthor et al, 30 except that stainless steel wires were used rather than carbon fibers. Extracellularly recorded signals of spiking ganglion cells were amplified conventionally and digitally stored via a Measurement Computing data acquisition boards (USB-1608 and USB-201, Measurement Computing Corp., Norton, MA) and analyzed offline as described below.…”
Section: Methodsmentioning
confidence: 99%
“…Extracellular recordings from single cells were obtained using a single carbon-fiber tipped, copper wire in-glass electrode plated with silver chloride (Amthor et al 2003;Armstrong-James and Millar 1979). The signal was amplified (A-M Systems, Sequim, WA), filtered with a custom-made learning filter to remove 60-Hz noise, thresholded with a custom-made Schmitt trigger, and digitized at a 1-kHz sampling rate using PCI-DAS1002 acquisition board (Measurement Computing, Norton, MA).…”
Section: Data Recording and Analysismentioning
confidence: 99%
“…For eyecup recordings, data were digitized and spike times detected using custom-template software described elsewherẽ Amthor et al, 2003!. For isolated-retina recordings, selected channels of data were digitized with a commercial data-acquisition system~Cyberkinetics!.…”
Section: Preparation and Recordingmentioning
confidence: 99%