1999
DOI: 10.1002/(sici)1522-726x(199907)47:3<381::aid-ccd29>3.0.co;2-#
|View full text |Cite
|
Sign up to set email alerts
|

A new thrombectomy catheter device (AngioJet) for the disruption of thrombi: An in vitro study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
12
0

Year Published

2002
2002
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(14 citation statements)
references
References 54 publications
2
12
0
Order By: Relevance
“…Our tests showed that for a given catheter, the vacuum pressures required to aspirate a 6‐ or 12‐hr thrombus were similar, the difference lying in the fact that 12‐hr thrombi are partially organized, as necroscopic studies have shown [9]. As the intervention takes place between 6 and 12 hr after MI onset, our findings are clinically valid.…”
Section: Discussionsupporting
confidence: 64%
See 2 more Smart Citations
“…Our tests showed that for a given catheter, the vacuum pressures required to aspirate a 6‐ or 12‐hr thrombus were similar, the difference lying in the fact that 12‐hr thrombi are partially organized, as necroscopic studies have shown [9]. As the intervention takes place between 6 and 12 hr after MI onset, our findings are clinically valid.…”
Section: Discussionsupporting
confidence: 64%
“…However, the chosen diameter was smaller than that of the epicardic arteries, which are generally treated by PCI (even more so for TA) [7, 8]. Moreover, the biomechanical properties of gelatin do not correspond to those of thrombi, which are the result of a dynamic process [9]. The impact of these choices was to limit the clinical relevance of the results.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The Angiojet catheters come in several diff erent diameters and lengths which suit for blood vessels of a variety of diameters. This system has the ability to clear a vessel much larger than the catheter diameter compared to other mechanical devices [7]. The device may be used alone, or following pharmacologic thrombolysis or standard catheter aspiration thrombectomy.…”
Section: Discussionmentioning
confidence: 99%
“…This process leads to the formation of a complex structure with different mechanical properties than fresh thrombus (7, 26). Accordingly, mechanical thrombectomy devices might be expected to perform differently in organized compared with fresh thrombus (27). Thus, the proposed model aimed to create a more “real life” thromboembolism.…”
Section: Discussionmentioning
confidence: 99%