2020
DOI: 10.1109/jestpe.2019.2903806
|View full text |Cite
|
Sign up to set email alerts
|

A New Three-Level Neutral-Point-Clamped Fifteen-Switch Inverter for Independent Control of Two Three-Phase Loads

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…The 3L inverter for controlling two 3-phase load individually is discussed in [29], however to improve the efficiency and performance of inverter drive the 5-phase load is chosen in this manuscript. The 5-phase 3L inverter which is capable of controlling two 5-phase loads is designed and analyzed.…”
Section: Table 5 Comparison Of Simulation and Experimental Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The 3L inverter for controlling two 3-phase load individually is discussed in [29], however to improve the efficiency and performance of inverter drive the 5-phase load is chosen in this manuscript. The 5-phase 3L inverter which is capable of controlling two 5-phase loads is designed and analyzed.…”
Section: Table 5 Comparison Of Simulation and Experimental Resultsmentioning
confidence: 99%
“…The NSI and FLI is available for controlling the 3-phase load with 2L output where the number of switches are reduced than conventional dual load inverter. However, the losses and THD is more in 2L inverter which leads to the introduction of 3L inverter with five switches in each leg [29]. Though 3-phase inverters are commercialized for their easier availability and good performance, the 5-phase inverters are gaining attraction in recent years where the losses and harmonic contents are further reduced as the voltage stress is decreased due to less operating period.…”
Section: Introductionmentioning
confidence: 99%
“…In order to facilitate the control of the energy of lithium battery and supercapacitor, they are connected to the DC bus with the help of two-level interleaved DC/DC converters. Through a three-level three-leg inverter, the energy output by the hybrid energy source is used to power two hub-type external rotor permanent magnet synchronous motors to drive tram operation [15]. The choice of level is based on a comprehensive consideration of cost, control complexity and output voltage waveform quality.…”
Section: Composition and Technical Parameters Of Hybrid Energy Storag...mentioning
confidence: 99%
“…This, Fifteen Switch Inverter topology contains 3 switches in each leg which produces 2L output for each motor. The 3L inverter for controlling 3-phase load is developed and their performances are observed in [211]. The bearing current is eliminated by introducing the Fourth-Arm technique in [214] which may be considered for 5phase inverters.…”
Section: Motivationmentioning
confidence: 99%