2009
DOI: 10.1107/s0909049509018986
|View full text |Cite
|
Sign up to set email alerts
|

A new small-angle X-ray scattering set-up on the crystallography beamline I711 at MAX-lab

Abstract: A small-angle X-ray scattering (SAXS) set-up has recently been developed at beamline I711 at the MAX II storage ring in Lund (Sweden). An overview of the required modifications is presented here together with a number of application examples. The accessible q range in a SAXS experiment is 0.009-0.3 A(-1) for the standard set-up but depends on the sample-to-detector distance, detector offset, beamstop size and wavelength. The SAXS camera has been designed to have a low background and has three collinear slit se… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
66
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 65 publications
(67 citation statements)
references
References 35 publications
1
66
0
Order By: Relevance
“…The synchrotron SAXS data were collected on the Beam Line I911-4 [21,22] at the MAXII storage ring of the MAX-Lab (Lund, Sweden) using the synchrotron radiation (λ = 0.091 nm) and the MarCCD 165 mm detector. The GNP samples were injected into thermostated capillary sample holder and the measurements were performed at room temperature.…”
Section: Saxsmentioning
confidence: 99%
See 1 more Smart Citation
“…The synchrotron SAXS data were collected on the Beam Line I911-4 [21,22] at the MAXII storage ring of the MAX-Lab (Lund, Sweden) using the synchrotron radiation (λ = 0.091 nm) and the MarCCD 165 mm detector. The GNP samples were injected into thermostated capillary sample holder and the measurements were performed at room temperature.…”
Section: Saxsmentioning
confidence: 99%
“…The detector s-axis was calibrated using silver behenate [23]. The data were normalized, corrected for detector response and integrated using SAXS data reduction software Bli711 [22]. The distance distribution function p(r) was calculated from the experimental scattering also by indirect Fourier transformation and the program GNOM [24].…”
Section: Saxsmentioning
confidence: 99%
“…The SAXS measurements were performed partly at the SAXS beamline I711 at MAX-lab, Lund, Sweden, 13 and partly at the ID14−3 beamline at ESRF, Grenoble, France. 14 Buffer backgrounds were measured before and after each sample, and the averaged background was subtracted from the sample measurement.…”
Section: ■ Experimental Methodsmentioning
confidence: 99%
“…Small-angle X-ray scattering (SAXS) measurements were conducted on beam line I711 at the MAX II storage ring in Lund, Sweden. 32 Microemulsion samples were enclosed in high-quality quartz capillaries with a diameter of 1.7 mm, glued in steel housings. A water sample, the solvent background, was measured in the same capillary and later subracted in the data treatment.…”
Section: Methodsmentioning
confidence: 99%
“…In addition, the prefactors in eqs 3-5 are given by expressions analogous to those for model A, M ( (ij) ) δ j ′Y ( δ i ′X, but where the δ i ′ functions are given by (32) in terms of the same δ i functions that enter model A, and which are given explicitly by Griffith et al 26 The functions X and Y are given by the same expressions as in model A, and they depend on a number of functions that are given by Griffith et al 26 These functions, however, are defined somewhat differently…”
Section: Appendixmentioning