2022
DOI: 10.1002/cta.3279
|View full text |Cite
|
Sign up to set email alerts
|

A new seven‐level ANPC inverter structure with semiconductor device reduction

Abstract: An active neutral point clamped‐type multilevel inverter (ANPC‐MLI) with self‐voltage balancing capability is being suggested for this study. A new switched capacitor cell with eight switches is used for seven‐level generation in the proposed topology. The topology proposed has decreased the power element count with the ability to self‐balancing of capacitor voltages and boosting ability. The distinguishing characteristics of the proposed topology are emphasized and compared with other recent 7L‐SCMLI topologi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
10
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 25 publications
0
10
0
Order By: Relevance
“…As evident from Table 4, the seven-level topologies [13][14][15] required low Ns but had a gain of 1.5 for previous works 13,14 and a gain of 3 for Sarwer et al. 15 As having a high gain in the seven-level inverter, 15 TSV increases resultant CF is high.…”
Section: Comparision With Other Multilevel Topologiesmentioning
confidence: 98%
See 2 more Smart Citations
“…As evident from Table 4, the seven-level topologies [13][14][15] required low Ns but had a gain of 1.5 for previous works 13,14 and a gain of 3 for Sarwer et al. 15 As having a high gain in the seven-level inverter, 15 TSV increases resultant CF is high.…”
Section: Comparision With Other Multilevel Topologiesmentioning
confidence: 98%
“…Proposed SC-MLI worked in an asymmetric charging state and uses only three capacitors. The topologies [13][14][15][16][17][18][19][20][21][22][23][24][25][26][27][28][29] generate different voltage levels and use single or multiple DC sources. Topologies [13][14][15] are operated with seven-level, where previous works 13,14 have the gain of 1.5.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…The CF of self‐balanced SCMLI mainly depends on the component count and TSV PU as shown in Equation (18). 23 The component count and (TSV + PIV) PU have to maintain a minimum to make the cost of the inverter low. Similarly, MBV and TCS MAX have to maintain the minimum to provide high efficiency.…”
Section: Comparative Analysismentioning
confidence: 99%
“…8,9 Considering in quite a lot industrial applications, bidirectional power flow is not required, 10,11 such as the AC adjustable speed motor drives with pumps or fans load, for such applications, the first configuration seems too complex and costly. In the latter a passive or an active filter is required in front end to mitigate input current harmonics produced by the diode rectifier, besides, it requires additional hardware installation to achieve voltage balancing control 12,13 of the DC-link split capacitors. 14 The cascaded multilevel converter based on high-frequency (HF) isolated DC/DC converter is another type of LF transformerless converter where the traditional LF transformers are removed.…”
Section: Introductionmentioning
confidence: 99%