2019
DOI: 10.5829/ije.2019.32.01a.08
|View full text |Cite
|
Sign up to set email alerts
|

A New Restricted Earth Fault Relay Based on Artificial Intelligence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(12 citation statements)
references
References 0 publications
0
10
0
Order By: Relevance
“…By applying these settings, a strict evaluation of the proposed method performance is achieved. Then, the detection accuracy of the proposed method is evaluated for a wide range of internal and external fault events in comparison with the conventional method and an intelligent method [17]. It must be noted that two methods are simulated using MATLAB program but there is no interface between this program and PSCAD.…”
Section: Simulation Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…By applying these settings, a strict evaluation of the proposed method performance is achieved. Then, the detection accuracy of the proposed method is evaluated for a wide range of internal and external fault events in comparison with the conventional method and an intelligent method [17]. It must be noted that two methods are simulated using MATLAB program but there is no interface between this program and PSCAD.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…To obtain a comprehensive and comparative assessment of the proposed method detection accuracy, its performance is evaluated for a wide range of internal and external faults in comparison with the conventional method [20] and the intelligent method [17]. To simulate internal fault events, voltage source is connected to the Y winding of power transformer under study and it supplies full-load power.…”
Section: A Comprehensive Comparative Accuracy Assessmentmentioning
confidence: 99%
See 1 more Smart Citation
“…As shown in Fig. 1, a part of a high voltage substation in Iran [21,22], including a power transformer, grounding transformer and CTs is modeled in PSCAD software. The specification of the power transformer and CTs are presented by Tables 1 and 2, respectively.…”
Section: Test Studymentioning
confidence: 99%
“…This model is based on the phenomenological model of a ferromagnetic core and the relationship between the magnetic moment and the intensity of the magnetic field. Currently used models, use mathematical techniques, which approximate the behavior of the hysteresis loop for recoil loops and renascence effects [22,23]. For many studies, these models are quite adequate except where accurate values of renascence are required following a circuit interruption with a subsequent reclose into a live circuit.…”
Section: Test Studymentioning
confidence: 99%