2006
DOI: 10.1016/s1569-9056(06)60877-4
|View full text |Cite
|
Sign up to set email alerts
|

A New Psa Sensitive Probe to Be Used for Pre-Operative Assessment of Extraprostatic Extension of Tumours

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…In this paper, we present a novel instrument developed by InvivoSense (formerly Optomed) utilizing an interferometric technique to measure gel swelling. More specifically, a hydrogel is chemically bound to the end of an optical fiber and makes up a Fabry−Perot cavity, which optical length can be determined with high precision.…”
mentioning
confidence: 99%
“…In this paper, we present a novel instrument developed by InvivoSense (formerly Optomed) utilizing an interferometric technique to measure gel swelling. More specifically, a hydrogel is chemically bound to the end of an optical fiber and makes up a Fabry−Perot cavity, which optical length can be determined with high precision.…”
mentioning
confidence: 99%
“…The complete set-up including hardware and LabView program for data collection was obtained from Invivosense ASA, Trondheim, Norway. The interferometric determination of the optical length in the hydrogel exploits a tunable super fluorescent Erdoped optical fiber source (wave-packet λ 0 = λ a − λ b = 1530-1560 nm) [61]. This IR signal used as the incident light is partly reflected at the fiber-hydrogel (reflection coefficient r 1 ) and hydrogel-immersing solution interfaces (reflection coefficient r 2 ), and a net reflected interference wave with amplitude and phase that change depending on the swelling of the hydrogel:…”
Section: Determination Of Biosensor Swelling Responsementioning
confidence: 99%
“…The cavity length, from equation (2), can be computed from the frequency of the spectral peak of the Fourier transform (FFT) of the normalized reflectance (3). Simply picking the frequency component with highest magnitude will not provide the needed accuracy, since the source bandwidth is only a few times the FSR of the Fabry-Perot sensor cavity.…”
Section: Sensor Length Estimationmentioning
confidence: 99%
“…We have used this technology for tissue PSA measurements [3] and glucose measurements [4,5]. In these earlier studies, we used readout instrumentation based on superfluorescent Er fiber source, a tunable optical fiber filter and PC based data acquisition and demonstrated nanometer length resolution from hydrogel sensors [6].…”
Section: Introductionmentioning
confidence: 99%