1986
DOI: 10.1536/ihj.27.661
|View full text |Cite
|
Sign up to set email alerts
|

A new portable device for 24-hour recording of ambulatory intra-arterial blood pressure and heart rate in hypertensive patients.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

1987
1987
2019
2019

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 3 publications
0
5
0
Order By: Relevance
“…Changes in heart rate (HR) and blood pressure over a 24-h period take place not in a disorderly fashion, but are influenced by several conditions (44)(45)(46)(47)(48). For example, during nocturnal sleep, HR and BP in normotensive and hypertensive subjects (28,45,46).…”
Section: Methods O F Calculating Positive Load and Negative Load Compomentioning
confidence: 99%
“…Changes in heart rate (HR) and blood pressure over a 24-h period take place not in a disorderly fashion, but are influenced by several conditions (44)(45)(46)(47)(48). For example, during nocturnal sleep, HR and BP in normotensive and hypertensive subjects (28,45,46).…”
Section: Methods O F Calculating Positive Load and Negative Load Compomentioning
confidence: 99%
“…Because of the high positive coefficient of correlation (r) between direct SBP and DBP (rϭ0.70 to 0.98), 11 we used the linearregression formula SBPϭaϫDBPϩb (where a is the regression coefficient and b is constant value) with sleep-time values to obtain the statistical base SBP (SBP 0 ) corresponding to DBP 0 : Values are meanϮSD. KW indicates Keith-Wagner grade: 0 -1ϭnormal or slightly narrowed retinal arteries, 2ϭgeneralized narrowing of retinal arteries, or nipping of veins, 3ϭretinopathy with hemorrhages and cotton-wool spots without papilledema; CTR, cardiothoracic ratio; and SV 1 ϩRV 5 , sum of S in V 1 lead and R in V 5 lead on electrocardiogram.…”
Section: Measurement Of Estimated Base Bp Values From Direct Recordingsmentioning
confidence: 99%
“…Incidentally, because controlling respiration itself may be a stress, respiratory control was not done in the present study. Measurements of ECG for which breathing is not regulated in this way are performed in many clinical studies (22,(24)(25)(26). Furthermore, analysis of autonomic nerve activity is based on the low probability of occurrence of respiratory arrhythmia due to mild stress loading in healthy young people and automatic elimination by the analysis device when an arrhythmia does occur.…”
Section: Discussionmentioning
confidence: 99%
“…Measurements. The subjects wore electrocardiography (ECG) electrodes (disposable monitoring electrode L bead load; Nihon Kohden Industry Co., Ltd.) attached to an ECG monitoring system (TM2425-ECG; A & D Company) (22). Subjects were examined during weekdays from 9 am to 12 am while being kept fasted.…”
Section: Subjectsmentioning
confidence: 99%