2008
DOI: 10.3390/s8031819
|View full text |Cite
|
Sign up to set email alerts
|

A New PC and LabVIEW Package Based System for Electrochemical Investigations

Abstract: The paper describes a new PC and LabVIEW software package based system for electrochemical research. An overview of well known electrochemical methods, such as potential measurements, galvanostatic and potentiostatic method, cyclic voltammetry and EIS is given. Electrochemical impedance spectroscopy has been adapted for systems containing large capacitances. For signal generation and recording of the response of investigated electrochemical cell, a measurement and control system was developed, based on a PC P4… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
3

Year Published

2009
2009
2019
2019

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 30 publications
(17 citation statements)
references
References 6 publications
0
13
0
3
Order By: Relevance
“…The system for electrochemical measurements consisted of hardware (PC, AD-DA converter NI-6251 produced by National Instruments [Austin, TX] and analog interface) and software for excitation and measurement (Lab-VIEW 8.2 platform and application software; National Instruments) both fully developed by Technical Faculty in Bor. [43] Good reproducibility was proved by repeating the experiments under the same conditions. The samples were prepared by the PM process using electrolytic copper powder and silver powder with purities of 99.7 and 99.9 pct, respectively (the silver powder content in the mixture was 4 at.…”
Section: Methodsmentioning
confidence: 99%
“…The system for electrochemical measurements consisted of hardware (PC, AD-DA converter NI-6251 produced by National Instruments [Austin, TX] and analog interface) and software for excitation and measurement (Lab-VIEW 8.2 platform and application software; National Instruments) both fully developed by Technical Faculty in Bor. [43] Good reproducibility was proved by repeating the experiments under the same conditions. The samples were prepared by the PM process using electrolytic copper powder and silver powder with purities of 99.7 and 99.9 pct, respectively (the silver powder content in the mixture was 4 at.…”
Section: Methodsmentioning
confidence: 99%
“…[21]. The use of VI under the graphical LabVIEW environment is advantageous for electrochemical measurements due to the flexible programming and the easyto-use, reliable and expandable instruments obtained [22,23].…”
Section: Software For Data Collectionmentioning
confidence: 99%
“…− elektrohemijske ćelije sa tri elektrode (radna, referentna i pomoćna), − hardvera (PC, AD/DA konvertor PCI-20428 W proizveden od strane Burr-Brown-a i analogni interfejs razvijen na Tehičkom fakultetu u Boru) [36], − softvera za merenje i upravljanje (LabVIEW 6 platforma i specijalno razvijena aplikacija za elektrohemijska merenja).…”
Section: Eksperimentalni Deounclassified