2019
DOI: 10.1007/s00216-019-01863-6
|View full text |Cite
|
Sign up to set email alerts
|

A new optimization strategy for MALDI FTICR MS tissue analysis for untargeted metabolomics using experimental design and data modeling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
27
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1
1

Relationship

2
7

Authors

Journals

citations
Cited by 18 publications
(27 citation statements)
references
References 43 publications
0
27
0
Order By: Relevance
“…Fresh frozen 10-µm sections of human muscle were mounted on conductive ITO-coated glass slides 75 × 25 mm (Bruker, Bremen, Germany) and stored at -80 °C until analysis. Matrix solutions were applied with an automatic microsprayer HTX TM-Sprayer (HTX Imaging, Chapel Hill, NC, USA) as previously described 49 . In the positive-ion mode, DHB matrix (30 mg mL -1 in MeOH/H 2 O 50:50 [v/v]) was deposited with the following parameters: nozzle temperature 80 °C, nozzle velocity 1200 mm min -1 , N 2 pressure 10 psi, N 2 flow rate 2 L min -1 , number of passes 12, flow rate 100 µL min -1 and track spacing 3 mm.…”
Section: Methodsmentioning
confidence: 99%
“…Fresh frozen 10-µm sections of human muscle were mounted on conductive ITO-coated glass slides 75 × 25 mm (Bruker, Bremen, Germany) and stored at -80 °C until analysis. Matrix solutions were applied with an automatic microsprayer HTX TM-Sprayer (HTX Imaging, Chapel Hill, NC, USA) as previously described 49 . In the positive-ion mode, DHB matrix (30 mg mL -1 in MeOH/H 2 O 50:50 [v/v]) was deposited with the following parameters: nozzle temperature 80 °C, nozzle velocity 1200 mm min -1 , N 2 pressure 10 psi, N 2 flow rate 2 L min -1 , number of passes 12, flow rate 100 µL min -1 and track spacing 3 mm.…”
Section: Methodsmentioning
confidence: 99%
“…Thus, employing our approach for future work will be faster and completely unbiased. Combining with other experimental optimization approaches, like that of ion transmission voltage optimization 21 and/or automated data acquisition optimization, 22 our approach using RSM for MALDI matrix application optimization can be valuable for attaining the most ideal spatial and chemical information from future MALDI-MSI analyses.…”
Section: Discussionmentioning
confidence: 99%
“…For example, in MALDI untargeted metabolomics analyses, this approach has been used for optimizing automated data acquisition parameters or ion transmission voltages and laser ablation parameters. 21,22 Here, we developed an experimental approach for optimizing MALDI matrix spraying conditions to minimize analyte delocalization and simultaneously maximize the number of detected lipids in MALDI-FTICR-MSI analysis of frozen human kidney biopsies. By testing 32 combinations of MALDI matrix spraying parameters with an automated spraying device, we were able to model, using RSM, the effect each of the spraying parameters had on the delocalization of endogenous molecules and the ability to detect and annotate lipid species.…”
Section: Introductionmentioning
confidence: 99%
“…Before each batch of analyses, external calibration was performed by sodium formate infusion via an ESI source. Lock mass calibration was performed at m/z 273.039364 (matrix ion 15 ) with FT MS control software (Bruker Daltonics, Bremen, Germany). Each spectrum encompassed 500 laser shots: laser focus, medium; laser power, 45%; laser spot, < 60 µm.…”
Section: Methodsmentioning
confidence: 99%