2021
DOI: 10.1016/j.ijepes.2021.107248
|View full text |Cite
|
Sign up to set email alerts
|

A new monitoring technique for fault detection and classification in PV systems based on rate of change of voltage-current trajectory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 24 publications
(6 citation statements)
references
References 29 publications
0
5
0
1
Order By: Relevance
“…The ADF method is adopted in this study to select the dimensions required for automatic diagnosis. ADF test values were calculated to determine the stationarity of data dimensions under different confidence levels [8], as shown in Figure 1. The data dimensions greater than 97% of the stationarity test results are extracted and used as the dimensions of behavior automatic diagnosis.…”
Section: Screen the Dimensions Of Consumption Behavior Datamentioning
confidence: 99%
“…The ADF method is adopted in this study to select the dimensions required for automatic diagnosis. ADF test values were calculated to determine the stationarity of data dimensions under different confidence levels [8], as shown in Figure 1. The data dimensions greater than 97% of the stationarity test results are extracted and used as the dimensions of behavior automatic diagnosis.…”
Section: Screen the Dimensions Of Consumption Behavior Datamentioning
confidence: 99%
“…Penelitian sebelumnya telah dilakukan beberapa penelitian mengenai monitoring kinerja panel surya [3], [7]- [15]. Pada penelitian [14], sistem monitoring kinerja panel surya memfokuskan pada output daya dari panel surya dengan mengukur tegangan dan arus keluaran panel surya.…”
Section: Pendahuluanunclassified
“…The authors of [19] deployed the voltage sensor by distinguishing the odevity of the number of the photovoltaic array string, meanwhile, formulated the positioning rules for each fault to achieve accurate location of faults. Abd El-Ghany et al [20] installed a diode in each photovoltaic string and adopted the change rate of instantaneous voltage and current to detect the fault of photovoltaic system. In [21], the authors normalized the sequence voltage and current of photovoltaic array, and gained the sequence power waveform of photovoltaic array by numerical calculation, finally used semi-supervised ladder network for fault diagnosis.…”
Section: Introductionmentioning
confidence: 99%