2021
DOI: 10.1016/j.poly.2020.114923
|View full text |Cite
|
Sign up to set email alerts
|

A new MOF-based fluorescent sensor for the detection of nitrofuran antibiotics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 51 publications
(14 citation statements)
references
References 41 publications
0
14
0
Order By: Relevance
“…More importantly, to verify the photoinduced electron transfer (PET) hypothesis, the LUMO and HOMO energy levels were calculated using DFT at the theoretical level of B3LYP/6-31G*. As can be seen in Figure S17, the LUMO energy levels of CIP and OFLX are higher than that of H 2 PIA ligand, reaching a possibility of electron transfer from the LUMO of OFLX and CIP to the LUMO of Eu-MOF, generating a fluorescence quenching of the Eu 3+ ion centers. Finally, the luminescence properties of OFLX and CIP solutions shown in Figure S18 exhibited an emission peak at 500 and 450 nm, as derived from the intrinsic luminescence of OFLX and CIP. Meanwhile, the fluorescence kinetics process is explored also.…”
Section: Results and Discussionmentioning
confidence: 99%
“…More importantly, to verify the photoinduced electron transfer (PET) hypothesis, the LUMO and HOMO energy levels were calculated using DFT at the theoretical level of B3LYP/6-31G*. As can be seen in Figure S17, the LUMO energy levels of CIP and OFLX are higher than that of H 2 PIA ligand, reaching a possibility of electron transfer from the LUMO of OFLX and CIP to the LUMO of Eu-MOF, generating a fluorescence quenching of the Eu 3+ ion centers. Finally, the luminescence properties of OFLX and CIP solutions shown in Figure S18 exhibited an emission peak at 500 and 450 nm, as derived from the intrinsic luminescence of OFLX and CIP. Meanwhile, the fluorescence kinetics process is explored also.…”
Section: Results and Discussionmentioning
confidence: 99%
“…The higher K SV value and lower detection limit make CUST-535 show greater advantages in MOF-based sensors. [37][38][39][40][41][42][43] (Table S4)…”
Section: Sensing Of Antibioticsmentioning
confidence: 99%
“…[5,6] As an important type of crystalline material, metal-organic frameworks (MOFs) [7,8] show adjustable structures, long fluorescence life, high color purity, some of which have been used to detect organic pollutants, [9] heavy metal ions [10][11][12] drug molecules, [13,14] and antibiotics. [15] For example, our group [16] developed a 5-chloro-8-hydroxyquinoline-based MOF to detect nitrofuran (NAF) antibiotics. At present, the research on tetracycline detection is usually based on fluorescence quenching, and the quenching mechanism can be divided into two types.…”
Section: Introductionmentioning
confidence: 99%