A New Miniaturized System for Monitoring the Epidural Pressure in Children and Adults

Abstract: A new miniaturized epidural pressure transducing system for monitoring intracranial pressure (ICP) has been developed. The system is of the as yet smallest known dimensions. The transducer is implanted automatically coplanar to the dura via a burr hole of 4 mm diameter in the conscious patient without special surgical equipment. Application is possible in adults, children and infants. We have achieved a maximal resolution of 10(-3) mm of Hg. At a full scale range of 100 mm of Hg the zero-point drift is less th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

1977
1977
1992
1992

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 23 publications
(2 citation statements)
references
References 8 publications
(11 reference statements)
0
2
0
Order By: Relevance
“…Furthermore, conventional therapy for the individual underlying brain damage, such as corticosteroid treatment, application of osmotic agents, control of blood pressure, and infusion of adequate amounts of cristalline and colloid fluids, was applied. 16 In all patients, ICP was measured with an epidural device 17 (Gaeltec Ltd., Dunvegan, Isle of Skye, Scotland). Arterial blood pressure was measured with a radial pressure transducer, and Paco 2 , Pao 2 , and pH were monitored by blood gas analysis.…”
Section: Methodsmentioning
confidence: 99%
“…Furthermore, conventional therapy for the individual underlying brain damage, such as corticosteroid treatment, application of osmotic agents, control of blood pressure, and infusion of adequate amounts of cristalline and colloid fluids, was applied. 16 In all patients, ICP was measured with an epidural device 17 (Gaeltec Ltd., Dunvegan, Isle of Skye, Scotland). Arterial blood pressure was measured with a radial pressure transducer, and Paco 2 , Pao 2 , and pH were monitored by blood gas analysis.…”
Section: Methodsmentioning
confidence: 99%
“…The left (LEP) and right (REP) epidural pressures were recorded parietally with special minia ture force transducers [4], The fronto-occipital bipolar EEG was recorded bilaterally by using silver screws. The EEG was evaluated continuously with a computer by FastFourier analysis [power spectra; 18], The power densities were calculated as total ( I -25 Hz), (8-(l-3.5 Hz), -8--(4-7.5 Hz) and a-(8-13.5 Hz) power1, and were separately drawn linearly in arbitrary units over the same time abscissa as the ICP.…”
Section: Methodsmentioning
confidence: 99%