2015
DOI: 10.1159/000380947
|View full text |Cite
|
Sign up to set email alerts
|

A New Method to Measure the Subpubic Arch Angle Using 3-D Ultrasound

Abstract: Objectives: The aim of this study was to assess the reproducibility of both a new contrast-enhancing technique (Oblique View eXtended Imaging, OVIX; Samsung) and the recently reported 3-D multiplanar technique (MPT) in the measurement of the subpubic angle (SPA) among a group of women at term gestation. In addition, we aimed to study the intermethod agreement between the OVIX technique and MPT. Methods: We acquired a transperineal 3-D ultrasound volume from 155 women with a singleton uncomplicated term pregnan… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 19 publications
(24 citation statements)
references
References 16 publications
0
24
0
Order By: Relevance
“…However, since the reproducibility of this technique was not assessed, we suspect that 2D measurement of the SPA may not adequately reliable to promote the use of this approach in clinical practice. On the other hand, 3D ultrasound may provide clear images of the pubic bone on the coronal plane, and thanks to the OVIX algorithm, accurate and reproducible measurements of the SPA may be simply and quickly obtained as previously demonstrated by our group [4]. …”
Section: Discussionmentioning
confidence: 87%
See 3 more Smart Citations
“…However, since the reproducibility of this technique was not assessed, we suspect that 2D measurement of the SPA may not adequately reliable to promote the use of this approach in clinical practice. On the other hand, 3D ultrasound may provide clear images of the pubic bone on the coronal plane, and thanks to the OVIX algorithm, accurate and reproducible measurements of the SPA may be simply and quickly obtained as previously demonstrated by our group [4]. …”
Section: Discussionmentioning
confidence: 87%
“…In all eligible women included in the study group 3D volume was acquired by transperineal ultrasound (fig. 1) and the SPA was visualized and measured by means of Oblique View Extended Imaging (OVIX) as described elsewhere [4]. OVIX is a 3D ultrasound contrast enhancement technique with excellent reproducibility for the measurement of SPA [4] (fig.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Classic pelvimetry based upon clinical or radiological examination has been abandoned due to its low accuracy, reproducibility, and costeffectiveness [3]. Very recently, the use of ultrasound has proved to be reliable in assessing the subpubic arch angle (SPA) [11,12], whose size is related to the transverse diameter of the birth canal [13]. Some independent studies have shown that, in the general population, a narrow SPA at antepartum ultrasound is associated with prolonged labor [14][15][16] and an increased risk of obstetric intervention [17,18].…”
Section: Correlation Between Subpubic Arch Angle and Mode Of Deliverymentioning
confidence: 99%