A new method of segmentation of compact-appearing, transitional and trabecular compartments and quantification of cortical porosity from high resolution peripheral quantitative computed tomographic images

Abstract: A transitional or cortico-trabecular junctional zone exists at any location composed of both cortical and trabecular bones such as the metaphyses of tubular bones and short bones like the femoral neck. The transitional zone comprises the inner cortex adjacent to the medullary canal and trabeculae abutting against the cortex contiguous with the endocortical surface. This is a site of vigorous remodeling. Intracortical remodeling cavitates the inner cortex expanding this transitional zone at the price of compact… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

5
231
1
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 174 publications
(240 citation statements)
references
References 39 publications
5
231
1
1
Order By: Relevance
“…Porosity within the total cortex and its compartments (compact cortex, outer and inner transitional zones), matrix mineralization density, trabecular number, thickness, separation, and bone volume/tissue volume (BV/TV) were quantified using StrAx1.0, a non-threshold-based method for quantifying microarchitecture in vivo. (34) The method automatically segments bone into its compartments (Straxcorp, Melbourne, Australia). The in vivo precision was 0.5 to 3.0%.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Porosity within the total cortex and its compartments (compact cortex, outer and inner transitional zones), matrix mineralization density, trabecular number, thickness, separation, and bone volume/tissue volume (BV/TV) were quantified using StrAx1.0, a non-threshold-based method for quantifying microarchitecture in vivo. (34) The method automatically segments bone into its compartments (Straxcorp, Melbourne, Australia). The in vivo precision was 0.5 to 3.0%.…”
Section: Methodsmentioning
confidence: 99%
“…The in vivo precision was 0.5 to 3.0%. (34) Daily quality control was carried out by scanning a phantom containing rods of hydroxyapatite (QRM, Moehrendorf, Germany).…”
Section: Methodsmentioning
confidence: 99%
“…8,11 Studies using high-resolution peripheral quantitative computed tomography (HR-pQCT) to quantify porosity (XtremeCT; Scanco Medical AG, Bruttisellen, Switzerland) present low values of porosity (between 1% and 15%) because of quantifying only porosity of the compactappearing cortex [12][13][14][15][16][17] and only pores over 100 mm, although 60% of cortical pores are under 100 mm in diameter. [18][19][20] This threshold-based image analysis underestimates porosity by including only completely empty voxels and excluding the voxels containing both void and bone matrix.…”
Section: Definition and Measurement Of Cortical Porositymentioning
confidence: 99%
“…[18][19][20] This threshold-based image analysis underestimates porosity by including only completely empty voxels and excluding the voxels containing both void and bone matrix. 11 Furthermore, direct measurements of cortical bone water content using deuterium oxide or dehydration experiments report a void volume between 15 and 40%, suggesting an under-reporting of porosity. [21][22][23] To avoid exclusion of voxels that contain both void volume and bone matrix, a new approach has been developed, taking into account this process of partial volume effect.…”
Section: Definition and Measurement Of Cortical Porositymentioning
confidence: 99%
See 1 more Smart Citation