A new method of harmonic power detection based on the instantaneous active power in three-phase circuits

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
35
0
3

Year Published

2007
2007
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 102 publications
(40 citation statements)
references
References 2 publications
0
35
0
3
Order By: Relevance
“…Given the harmonic voltage and current at a given frequency, in accordance with [4], the harmonic power flow approach based on the individual values of ܲ establishes that • The fundamental harmonic power, once calculated, will have either a positive or a negative sign. In the absence of consumer internal generation, this power is always taken as being positive.…”
Section: The Harmonic Power Flow Method: Definition and Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…Given the harmonic voltage and current at a given frequency, in accordance with [4], the harmonic power flow approach based on the individual values of ܲ establishes that • The fundamental harmonic power, once calculated, will have either a positive or a negative sign. In the absence of consumer internal generation, this power is always taken as being positive.…”
Section: The Harmonic Power Flow Method: Definition and Analysismentioning
confidence: 99%
“…However, it does not provide the means to share the responsibility between the supplier and the consumer. Therefore, this strategy can be considered as only a first step toward the identification of the total harmonic distortion responsibility, and its fundamentals have been fully described by many publications [4,5,6]. Based on these assumptions, several commercially-available power quality meters have the ability to measure individual voltage and current distortions and provide total values for these variables, and, in addition to these features, the majority of these devices provide the required harmonic power for each specific harmonic order.…”
Section: Introductionmentioning
confidence: 99%
“…Several methodologies for detecting harmonic sources have been applied to calculate the harmonic contributions at the point of common coupling. The most common tool to solve this problem is the harmonic power direction-based method [36][37][38] in which the symmetrical balanced or unbalanced and symmetrical three-phase harmonic power flows are detected. Another group of practical methods for harmonic source detection is to measure the utility and customer harmonic impedances and then calculate the harmonic sources behind the impedances.…”
Section: Harmonic Sources and Its Identificationmentioning
confidence: 99%
“…Then many algorithms are available to detect harmonic currents and generate the reference signal for the APF. Conventional detecting methods for harmonic currents include the digital low-pass or high-pass filters, the Fast Fourier Transform (FFT) [2] and the method based on instantaneous reactive power theory [3]. However they all have some limitations.…”
Section: Harmonic Currents For Active Power Filtermentioning
confidence: 99%