A New Method for Space Charge Measurements Under Periodic Stress of Arbitrary Waveform by the Pulsed Electro-Acoustic Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
14
0
1

Year Published

2008
2008
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(20 citation statements)
references
References 15 publications
5
14
0
1
Order By: Relevance
“…The charge density profiles of Al/LDPE (Fig.3) points out that Al electrodes provide negative charges at low field and no specific injection enhancement for high fields. Space charge results of In and Ag/ LDPE suggest that high electric field facilitates positive charge injection and higher conduction current while Al/LDPE with a large amount of negative space charge has a lower conduction current than In and Ag electrodes, so we can believe that the conduction current is controlled mostly by positive charges, which appears fairly consistent with the higher mobility reported for holes in the investigated material [8]. The barrier height for the injection without surface states is expressed by (Fig.4):…”
Section: B Space-charge Measurementsupporting
confidence: 79%
“…The charge density profiles of Al/LDPE (Fig.3) points out that Al electrodes provide negative charges at low field and no specific injection enhancement for high fields. Space charge results of In and Ag/ LDPE suggest that high electric field facilitates positive charge injection and higher conduction current while Al/LDPE with a large amount of negative space charge has a lower conduction current than In and Ag electrodes, so we can believe that the conduction current is controlled mostly by positive charges, which appears fairly consistent with the higher mobility reported for holes in the investigated material [8]. The barrier height for the injection without surface states is expressed by (Fig.4):…”
Section: B Space-charge Measurementsupporting
confidence: 79%
“…Meanwhile, the charge migration depth inside the sample is less than 20 μm. By contrast, there is obvious difference between the charge distributions at different frequencies under bipolar conditions, which is consistent with the experimental phenomenon that more charge accumulates at lower frequencies in [24]. The charge migration depth is only about 5 μm, which further indicates that due to the spatial resolution, the measurement systems in the Introduction cannot accurately observe the charge distribution inside the sample adjacent to the electrode interface under such conditions.…”
Section: Influence Of Frequency and Amplitude Of Polarization Conditionssupporting
confidence: 81%
“…However, increasing temperature undoubtedly breaks the rule with negative charge accumulation clearly observable at 10Hz and 50°C. Measurements up to 50Hz are achievable with the actual PEA hardware with careful prevention of surface and corona discharges in the environment of samples [6,9]. As measurements can be achieved safely up to 6kV voltage only at 50Hz [9], they were not attempted in the present set.…”
Section: Discussionmentioning
confidence: 99%
“…Measurements up to 50Hz are achievable with the actual PEA hardware with careful prevention of surface and corona discharges in the environment of samples [6,9]. As measurements can be achieved safely up to 6kV voltage only at 50Hz [9], they were not attempted in the present set. However, we can reasonably anticipate that long enough stressing time at the industrial frequency would also lead to charge accumulation.…”
Section: Discussionmentioning