A new method for calculating the thermal effects of irregular internal mass in buildings under demand response

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
2
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…Other studies have also shown that it is important to consider the thermal mass of furniture, especially in lightweight structure buildings [28,29]. The furniture is usually represented by simplified geometries in such analysis [30][31][32]. Wallentén [33] measured the heat transfer coefficient of walls of a room with and without furniture the effect of the furniture was not significant in this study.…”
Section: Effect Of Radiator Position Furniture and Occupantsmentioning
confidence: 66%
“…Other studies have also shown that it is important to consider the thermal mass of furniture, especially in lightweight structure buildings [28,29]. The furniture is usually represented by simplified geometries in such analysis [30][31][32]. Wallentén [33] measured the heat transfer coefficient of walls of a room with and without furniture the effect of the furniture was not significant in this study.…”
Section: Effect Of Radiator Position Furniture and Occupantsmentioning
confidence: 66%
“…Recent R&D focus on the thermal mass topic lies on the development of optimal operation strategies for building thermal processes, taking the TES by thermal mass factor into account. These thermal mass include the building structure (external and internal walls) [209], earths [92], internal furniture and contents [97,98], stored products in warehouses [201], or water-filled containers [99]. Some examples are shown in Fig.…”
Section: Thermal Massmentioning
confidence: 99%
“…Reynders et al used the structural thermal storage for demand-side management, offering the flexibility to improve the balance between electricity demand and production [9]. Besides indoor air and building envelope, Li et al also considered thermal mass of furniture in buildings and proposed a new method to calculate the equivalent thermal mass of actual furniture which has irregular shapes [10]. To quantify energy flexibility in buildings, Hurtado et al utilized several parameters including comfort capacity which represents the maximum response time before reaching comfort limits to describe the flexibility action of buildings [11].…”
Section: Introductionmentioning