2019
DOI: 10.1016/j.rinp.2019.102817
|View full text |Cite
|
Sign up to set email alerts
|

A new methane sensor based on compound film-coated photonic crystal fiber and Sagnac interferometer with higher sensitivity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 20 publications
0
8
0
Order By: Relevance
“…The reason for the above phenomenon was that the cladding hole had a great binding effect on the core energy and prevented the coupling between the core mode and the metal film. 1.99 nm/% 0 % -3.5% SPR [30] 4.03 nm/% 0 % -3.5% LPFG [19] 2.5 nm/% 0 % -3.5% Intermodal interference [21] 0.514 nm/% 0 % -3.5% Sagnac interference [32] 36.64 nm/% 0 % -3.5% SPR (this work) 9.88 nm/% 0 % -3.5%…”
Section: Resultsmentioning
confidence: 62%
See 1 more Smart Citation
“…The reason for the above phenomenon was that the cladding hole had a great binding effect on the core energy and prevented the coupling between the core mode and the metal film. 1.99 nm/% 0 % -3.5% SPR [30] 4.03 nm/% 0 % -3.5% LPFG [19] 2.5 nm/% 0 % -3.5% Intermodal interference [21] 0.514 nm/% 0 % -3.5% Sagnac interference [32] 36.64 nm/% 0 % -3.5% SPR (this work) 9.88 nm/% 0 % -3.5%…”
Section: Resultsmentioning
confidence: 62%
“…In reference [19], gas sensing using grating had the characteristics of fast response, but its sensitivity was not high. In reference [21,32] The advantages of interferometric optical fiber methane sensor are accurate measurement and high sensitivity. Its disadvantage is that it is greatly affected by temperature, humidity and air pressure and cannot meet the requirements of distributed sensing.…”
Section: Resultsmentioning
confidence: 99%
“…In [11] the sensor is based on the MZI principle, which has the disadvantage of low sensitivity. In [31] the sensor based on the principle of SI, has higher sensitivity compared to previously reported fiber sensors filled with cryptophane-A. However, its disadvantage lies in the fact that abrasion can reduce the strength of the fiber.…”
Section: Resultsmentioning
confidence: 93%
“…Fiber gratings are not the optimal choice due to their high production cost, complicated production process, and insufficient sensitivity, which makes it difficult to monitor changes in the number of parameters. Many researchers chose to use SI in the measurement of multiple parameters [28][29][30][31]. In the Sagnac loop, a fixed-length polarization maintaining fiber (PMF) with a fixed birefringence coefficient is sandwiched between two SMFs.…”
Section: Introductionmentioning
confidence: 99%