2002
DOI: 10.1109/15.990717
|View full text |Cite
|
Sign up to set email alerts
|

A new immunity test method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2003
2003
2008
2008

Publication Types

Select...
7
1

Relationship

4
4

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 5 publications
0
8
0
Order By: Relevance
“…The rotating-EM field in a two-dimensional plane can be generated by composing two-EM fields of horizontal and vertical polarization expressed as (1) and (2), respectively [7]. Where ω and Ω are angular frequencies of carrier and rotating rate of the polarization, respectively, and these signals are double-sideband suppressed carrier (DSB-SC) signals.…”
Section: B Generation Methods Of Rotating-em Fieldmentioning
confidence: 99%
See 1 more Smart Citation
“…The rotating-EM field in a two-dimensional plane can be generated by composing two-EM fields of horizontal and vertical polarization expressed as (1) and (2), respectively [7]. Where ω and Ω are angular frequencies of carrier and rotating rate of the polarization, respectively, and these signals are double-sideband suppressed carrier (DSB-SC) signals.…”
Section: B Generation Methods Of Rotating-em Fieldmentioning
confidence: 99%
“…A RF radiated immunity/susceptibility test method using rotating-EM fields is proposed [7], [8]. In this method, since the polarization of the EM fields rotates at a very low rate, e.g., below 1 Hz, the EM fields of whole polarization in a two-dimensional plane can be applied to EUT automatically.…”
Section: Introductionmentioning
confidence: 99%
“…Authors have proposed a radiated immunity/susceptibility test method using a rotating-EM field [5]. The rotating-EM field means an EM field whose polarization slowly rotates in a two dimensional plane.…”
Section: Introductionmentioning
confidence: 99%
“…The rotating-EM field can be generated by applying two different DSB-SC signals to two orthogonally arranged antennas [1]. These two DSB-SC signals are given by…”
Section: Dsb-sc Signal Generatormentioning
confidence: 99%
“…Recently, a radio frequency (RF) radiated immunity/susceptibility test method using the rotating electromagnetic fields (rotating-EM fields) was proposed [1]. In this method, EM fields with slowly rotating polarization are used as incident EM fields to equipment under test (EUT).…”
Section: Introductionmentioning
confidence: 99%