2018
DOI: 10.1016/j.seta.2017.12.006
|View full text |Cite
|
Sign up to set email alerts
|

A new idea for improving the horizontal straight ground source heat exchangers performance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 11 publications
0
6
0
1
Order By: Relevance
“…Este trabalho apresenta simulações de TCSA a partir de dados climáticos da cidade de Viamão, Rio Grande do Sul, cujas coordenadas geográficas são (30 o 04' 51"S; 51 o 01' 24" O). Além do trocador, utilizou-se uma caixa galvanizada ao redor do duto, para aumentar a condutividade térmica do solo circundante, avaliando adaptações das ideias apresentadas em Hassanzadeh et al (2018). A fim de concluir qual o melhor tamanho para a caixa galvanizada, os autores dividiram a pesquisa em nove casos, onde a proporção da caixa variou de 10 a 90%.…”
Section: Metodologiaunclassified
“…Este trabalho apresenta simulações de TCSA a partir de dados climáticos da cidade de Viamão, Rio Grande do Sul, cujas coordenadas geográficas são (30 o 04' 51"S; 51 o 01' 24" O). Além do trocador, utilizou-se uma caixa galvanizada ao redor do duto, para aumentar a condutividade térmica do solo circundante, avaliando adaptações das ideias apresentadas em Hassanzadeh et al (2018). A fim de concluir qual o melhor tamanho para a caixa galvanizada, os autores dividiram a pesquisa em nove casos, onde a proporção da caixa variou de 10 a 90%.…”
Section: Metodologiaunclassified
“…The continuous circulation of hot water in the buried pipes inside the soil will cause a clear change in its temperature, especially those adjacent to the pipe, which negatively affects the efficiency of heat transfer and the thermal performance of the buried pipe. , When using shallow soils for cooling PVT systems, the working fluid must be non-toxic to the soil when it is drained. Therefore, pure water is usually used as a cooling fluid in these systems. , Parameters such as the heat exchanger inlet temperature and coolant flow rate play an influential role in the overall thermal performance of the system. , …”
Section: Introductionmentioning
confidence: 99%
“…The method established by Hassanzadeh et al [9] shown that the applied heat transfer augmentation strategy was more effective for soils with a lower conductivity than those with a higher conductivity. The findings demonstrated that after the underground pipes of GSHEs are placed with galvanised bridges, the heat transfer capacity between the pipes and the ground improves significantly compared to standard GSHEs.…”
Section: Introductionmentioning
confidence: 99%