11th IET International Conference on AC and DC Power Transmission 2015
DOI: 10.1049/cp.2015.0068
|View full text |Cite
|
Sign up to set email alerts
|

A new HVDC grid test system for HVDC grid dynamics and protection studies in EMT-type software

Abstract: This paper proposes a new HVDC grid test system for electromagnetic transient analysis, suitable for HVDC power system studies ranging from protection to dynamic studies investigating converter behaviour and interactions. In the recent past research interest in HVDC grids has increased, leading to a multitude of studies concerning dc power flow and optimal power flow, dynamics and HVDC grid protection. However, each of these studies makes use of different grid topologies, configurations and transmission line p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
108
0
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 110 publications
(109 citation statements)
references
References 15 publications
0
108
0
1
Order By: Relevance
“…The simulation is performed in Matlab/SIMULINK environment. The parameters, Table I, and the modelling approach are adopted from [9]. The dc voltage reference is set at v (8) and (9) and (9) directly.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…The simulation is performed in Matlab/SIMULINK environment. The parameters, Table I, and the modelling approach are adopted from [9]. The dc voltage reference is set at v (8) and (9) and (9) directly.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…Figs. 2a-2b show the frequency dependency of r and l for a 320 kV XLPE cable for VSC HVDC transmission with data from [28]. Figs.…”
Section: Steady-state Cable Modelmentioning
confidence: 99%
“…In this paper, the parameters for the cable geometry and materials are taken from [18]. The parameters in (11) are obtained via the PSCAD TM Line Constants Program [19].…”
Section: Cable Characteristic Impedancementioning
confidence: 99%
“…Main parameters of the converter model, taken from [22] are given in Table 1. The simulated impedance response are calculated using frequency sweeping on a continuous MMC model implemented in PSCAD TM [18]. Figure 2 shows that first, the operating point of the converter influences the converter impedance in the low frequency region.…”
Section: Equivalent Impedance Of MMC Convertersmentioning
confidence: 99%
See 1 more Smart Citation