1996
DOI: 10.1002/(sici)1097-0231(19960731)10:10<1175::aid-rcm636>3.3.co;2-c
|View full text |Cite
|
Sign up to set email alerts
|

A New High‐performance Interface for Capillary Electrophoresis/Electrospray Ionization Mass Spectrometry

Abstract: A novel capillary electrophoresis electrospray ionization mass spectrometry (CE/ESI-MS) interface has been developed based upon an alternative means of establishing electrical contact at the CE capillary terminus. In this design, the terminus of the CE separation capillary and a short ESI emitter capillary are connected and sheathed by polysulphone micro-dialysis tubing. The electrical connection, to close the CE circuit and simultaneously establish the electrospray voltage, is provided outside the membrane vi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
33
0

Year Published

2000
2000
2009
2009

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 22 publications
(33 citation statements)
references
References 0 publications
0
33
0
Order By: Relevance
“…On the contrary, a sensitivity decrease (factor about 2) was observed in the presence of formic acid. In contrast to ESI, where an acid in the sheath liquid is mandatory to assist positive ionization [56,[59][60][61], the presence of a protic solvent in the sheath liquid appeared sufficient for photoionization.…”
Section: Sheath Liquid Compositionmentioning
confidence: 99%
See 1 more Smart Citation
“…On the contrary, a sensitivity decrease (factor about 2) was observed in the presence of formic acid. In contrast to ESI, where an acid in the sheath liquid is mandatory to assist positive ionization [56,[59][60][61], the presence of a protic solvent in the sheath liquid appeared sufficient for photoionization.…”
Section: Sheath Liquid Compositionmentioning
confidence: 99%
“…As expected, an increase in NebuP negatively influenced efficiency because of the pressure-induced flow in the capillary, known as "suction effect" [56,61]. Therefore, it was kept at its lowest value (10 psi) to avoid large losses in efficiency (up to 80% with 40 psi).…”
Section: Screening Of the Most Important Operating Factorsmentioning
confidence: 99%
“…One such example involves an open hole where a CE capillary is connected to the nanoelectrospray emitter, where the entire union is immersed in electrolyte in a pressurized vessel containing the electrode (Fanali et al, 2006). Another example uses microdialysis tubing as a union between the CE capillary and emitter which is immersed in liquid inside a plastic pipette tip also containing an electrode (Severs, Harms, & Smith, 1996). Edwards et al (2006) actually etched a porous hole in the side of their CE capillary upstream of the emitting end that served as a junction, this section being immersed in electrolyte in the presence of an electrode.…”
Section: Mode Of Electrical Contactmentioning
confidence: 99%
“…Among the sheathless CE/MS techniques, the gold‐coated fused‐silica capillary method is the most popular one 11–13. In general, the fabrication of gold‐coated tapered capillaries requires special equipment and is also time‐consuming 14–16. In addition, the coated tips have a limited lifetime.…”
mentioning
confidence: 99%