2016
DOI: 10.1016/j.snb.2016.05.166
|View full text |Cite
|
Sign up to set email alerts
|

A new graphene-based surfactant sensor for the determination of anionic surfactants in real samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0
1

Year Published

2017
2017
2021
2021

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 23 publications
(10 citation statements)
references
References 24 publications
0
9
0
1
Order By: Relevance
“…The detection limits were estimated according to the IUPAC recommendations. [19] The investigated sensor revealed a sub-Nernstian response for both DS and DBS in H2O (57.1 and 54.4 mV/decade of activity, respectively) between 3.2 · 10 −7 and 5.0 · 10 −3 M for dodecyl sulfate (DS) and 4.5 · 10 −7 and 1.2 · 10 −3 M for dodecylbenzenesulfonate (DBS).…”
Section: Response Characteristicsmentioning
confidence: 96%
See 2 more Smart Citations
“…The detection limits were estimated according to the IUPAC recommendations. [19] The investigated sensor revealed a sub-Nernstian response for both DS and DBS in H2O (57.1 and 54.4 mV/decade of activity, respectively) between 3.2 · 10 −7 and 5.0 · 10 −3 M for dodecyl sulfate (DS) and 4.5 · 10 −7 and 1.2 · 10 −3 M for dodecylbenzenesulfonate (DBS).…”
Section: Response Characteristicsmentioning
confidence: 96%
“…At all the selectivity measurements, DS was used as the analyte, in the range from 2 · 10 −6 M to 2 · 10 −3 M, whereas the concentration of the interfering ion was 0.01 M. DDA-TPB + 10 % C [5] DDA-TPB + graphene [19] L 1 [22] PPy-DBS [23] Interference The new FCNSS exhibited excellent selectivity for DS over all of the anions investigated. Comparing with other potentiometric surfactant sensors, FCNSS revealed superior selectivity performances.…”
Section: Determination Of the Potentiometric Selectivity Coefficientsmentioning
confidence: 99%
See 1 more Smart Citation
“…AS‐selective electrodes meet all of these requirements (Barό‐Romà et al, ; Birch and Clarke, ; Ishibashi et al, ; Makarova and Kulapina, , ; Samardžić et al, ). Recently, there has been a great effort invested in creating an AS‐selective electrode with an improved detection limit, selectivity, accuracy, and response time, so many different types of AS‐selective electrodes with different membrane components are being used (Abounassif et al, ; Alegret et al, ; Galović et al, ; Ghaedi et al, ; Seguí et al, ; Wang et al, ).…”
Section: Introductionmentioning
confidence: 99%
“…Пропонують різні методи виявлення неіонних поверхнево-активних речовин [2][3][4][5][6], які потребують складних аналітичних інструментів [3,5]. Однак є потреба у проведенні аналізу з використанням простого та широкодоступного аналітичного обладнання.…”
unclassified