2013
DOI: 10.1109/tdei.2013.6678888
|View full text |Cite
|
Sign up to set email alerts
|

A new fuzzy logic approach for consistent interpretation of dissolved gas-in-oil analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
60
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 113 publications
(60 citation statements)
references
References 15 publications
0
60
0
Order By: Relevance
“…Fuzzy logic is widely applied for dissolved gas analysis (DGA) of power transformers [13,14] since DGA contains relatively many input parameters. If binary logic is used a contradiction can occur, where some of the input parameters correspond with a good condition but others with a bad condition.…”
Section: General Description Of Oil Indicator Algorithmmentioning
confidence: 99%
“…Fuzzy logic is widely applied for dissolved gas analysis (DGA) of power transformers [13,14] since DGA contains relatively many input parameters. If binary logic is used a contradiction can occur, where some of the input parameters correspond with a good condition but others with a bad condition.…”
Section: General Description Of Oil Indicator Algorithmmentioning
confidence: 99%
“…1  and 2  were set at 50 ppm for all MFs of hydrogen, and at 25, 2, 6 and 5 ppm for all MFs of CH4, C2H2, C2H4 and C2H6 respectively. These values lead to an overlap of 25% between adjacent MFs, as seen in Figure 2, and yield more accurate oil health indexes than MFs based on precise sets [3], [8]- [12], [20]. Additional information on MFs and degrees of membership can be found in [22] and [23].…”
Section: Membership Functions and Degrees Of Membershipmentioning
confidence: 99%
“…It has been reported in the literature that the service lifetime of power transformers is determined mainly by the lifetime of their insulation [3]. During normal operation, electrical and thermal stresses cause deterioration of the transformer oil and paper insulation, leading to accumulation of gases within the transformer oil.…”
Section: Introductionmentioning
confidence: 99%
“…Its running state can directly affect the reliability of the entire power supply and system stability. Through an analysis of the dissolved gas in the oil, we can obtain the operation status of the transformer to determine the type of failure and can timely detect the potential risk of transformer operation failure [1][2][3][4]. It is important to study the prediction of dissolved gas concentration in oil, and its prediction results can provide a reference value for transformer state evaluation.…”
Section: Introductionmentioning
confidence: 99%