2015
DOI: 10.1007/s11270-014-2281-6
|View full text |Cite
|
Sign up to set email alerts
|

A New Functionalized Resin for Preconcentration and Determination of Cadmium, Cobalt, and Nickel in Sediment Samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
3
0
4

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 25 publications
1
3
0
4
Order By: Relevance
“…The limit of detection (LOD) and the relative standard deviation (RSD, n = 6) of Cd were 0.1 µg/L and 1.0% with a preconcentration factor of 10, respectively. The LOD that was obtained in this study was the same as that reported by using resin for preconcentration [14], both are one magnitude smaller than the value obtained by using amino-functionalized mesoporous sorbent for Cd(II) preconcentration [22].…”
Section: Limit Of Detectionsupporting
confidence: 76%
See 1 more Smart Citation
“…The limit of detection (LOD) and the relative standard deviation (RSD, n = 6) of Cd were 0.1 µg/L and 1.0% with a preconcentration factor of 10, respectively. The LOD that was obtained in this study was the same as that reported by using resin for preconcentration [14], both are one magnitude smaller than the value obtained by using amino-functionalized mesoporous sorbent for Cd(II) preconcentration [22].…”
Section: Limit Of Detectionsupporting
confidence: 76%
“…Therefore, preconcentration is necessary during analytical procedures [5,13]. Adsorbents, like chelating resins [14], mesoporous sorbent [15], etc., have been investigated for the preconcentration of Cd(II) in water samples. However, a desorption process was needed after preconcentration with these solid adsorbents, which made the analytic process complicated, time-consuming, and the recovery ratio was not good because of the incomplete desorption.…”
mentioning
confidence: 99%
“…The tolerance limit of ± 5% was considered for the interfering species, which is commonly applied in other studies. 36,37 Other species frequently present in the matrix such as alkali and alkaline earth metals do not form stable complexes under the optimized conditions for this system.…”
Section: Iip Selectivitymentioning
confidence: 97%
“…A vazão da amostra é importante porque está diretamente relacionada com o tempo de contato entre os analitos e o absorvente HDL (Lemos et al, 2015).…”
Section: Estudo Da Vazão De Pré-concentraçãounclassified
“…Uma vazão adequada/ótima para a eluição depende do quanto fortemente o analito está retido no sorvente e na força de dessorção do eluente. O estudo da vazão tem influência sobre a fase de pré-concentração e de eluição, uma vez que controla o tempo de contato entre a amostra, eluente e adsorvente(Lemos et al, 2015). Sabendo que a vazão do eluente na etapa de eluição pode A massa do adsorvente também foi avaliada por estar diretamente ligada a eficiência de extração, uma vez que define o número de sítios ativos para troca iônica.…”
unclassified