2004
DOI: 10.1039/b408940p
|View full text |Cite
|
Sign up to set email alerts
|

A new FTIR-ATR cell for drug diffusion studies

Abstract: The drug diffusion of most compounds, particularly hydrophilic molecules through the skin is limited by the permeation of the outermost cell layers of the epidermis, the stratum corneum(SC). For this reason it is of interest to characterize drug diffusion processes through this skin layer. A new FTIR-ATR cell was developed for non-invasive real time measurements of drug diffusion. The diffusion of water through an artificial polyethyleneglycol-polydimethylsiloxane membrane was studied. Additionally the diffusi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2006
2006
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 6 publications
0
10
0
Order By: Relevance
“…Wartewig and coworkers modified the geometry of such measurements to incorporate an acceptor layer between the donor (i.e., drug formulation) and membrane to be studied. 35,36 A number of examples of this approach are given in a review by Wartewig and Neubert, 37 and the reader is advised to examine this article and the references therein for more detail. Kazarian et al 38 used ATR/FT-IR imaging to study the hydration and dissolution kinetics of a number of hydroxy propyl methyl cellulose (HPMC)-based binary pharmaceutical formulations.…”
Section: Volatile Componentmentioning
confidence: 98%
“…Wartewig and coworkers modified the geometry of such measurements to incorporate an acceptor layer between the donor (i.e., drug formulation) and membrane to be studied. 35,36 A number of examples of this approach are given in a review by Wartewig and Neubert, 37 and the reader is advised to examine this article and the references therein for more detail. Kazarian et al 38 used ATR/FT-IR imaging to study the hydration and dissolution kinetics of a number of hydroxy propyl methyl cellulose (HPMC)-based binary pharmaceutical formulations.…”
Section: Volatile Componentmentioning
confidence: 98%
“…9,10 It is also able to measure humidity variations 11 and the structure of lipid bilayers. 12 In this context, Fourier transform infrared ͑FTIR͒ spectroscopic imaging was applied to skin to measure the heterogeneity of the skin at a microscopic level.…”
Section: Introductionmentioning
confidence: 99%
“…The permeation experiments were conducted with the IFS 28 spectrometer and an ATR measuring unit from Thermo Spectra Tech with the Teflon diffusion cell developed by Hartmann et al [32] and modified by Günther [33] (Fig. 2).…”
Section: Methodsmentioning
confidence: 99%