A new fluorescent probe for sensing of biothiols and screening of acetylcholinesterase inhibitors

Abstract: An axial N2O-type BODIPY probe has been proposed for sensitive and selective sensing of biothiols and screening of AChE inhibitors using a fluorescence turn-on assay.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 50 publications
0
5
0
Order By: Relevance
“…The results showed that the fluorescence intensities versus GSH, Cys, and Hcy were linear up to 1 μM ( Figure 4 ). The limit of detections (LODs) for GSH, Cys, and Hcy were calculated as low as 13.4, 4.5, and 18.3 nM, respectively, according to the equation LOD = 3 S/K [ 29 , 30 ], where S is the standard deviation of fluorescence for blank and K is the slope of the calibration plot. These LOD and the linear range values are among the best results of those recently reported biothiol sensors ( Table S1 ), revealing high sensitivity of the present system.…”
Section: Resultsmentioning
confidence: 99%
“…The results showed that the fluorescence intensities versus GSH, Cys, and Hcy were linear up to 1 μM ( Figure 4 ). The limit of detections (LODs) for GSH, Cys, and Hcy were calculated as low as 13.4, 4.5, and 18.3 nM, respectively, according to the equation LOD = 3 S/K [ 29 , 30 ], where S is the standard deviation of fluorescence for blank and K is the slope of the calibration plot. These LOD and the linear range values are among the best results of those recently reported biothiol sensors ( Table S1 ), revealing high sensitivity of the present system.…”
Section: Resultsmentioning
confidence: 99%
“…Secondly, a boronate fluorescent probe is utilized for the detection of the h202 generation [50]. Lastly, there are probes specifically designed for screening acetylcholinesterase inhibitors [51].…”
Section: Fluorescent Probes For Tissues and Organsmentioning
confidence: 99%
“…Among all these, the fluorescence spectroscopic assay is one of the most commonly used methods, as it has high sensitivity and easy accessibility for high-throughput screening. 9 Traditional fluorescence analysis relies on the changes of intrinsic fluorescence from HSA tryptophan residues. 10 However, the intrinsic fluorescence has a wavelength typically ranging from ultraviolet (UV) to blue light, which is easily subject to interferences due to the presence of other fluorescent biomolecules and drugs.…”
Section: Introductionmentioning