2000
DOI: 10.1016/s0009-2614(00)00687-4
|View full text |Cite
|
Sign up to set email alerts
|

A new energy transfer chemical laser at 1.315 μm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
49
0

Year Published

2002
2002
2010
2010

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 55 publications
(50 citation statements)
references
References 24 publications
1
49
0
Order By: Relevance
“…The Cl / HN 3 stoichiometry suggests that the optimum 28 condition for NCl(a'A) production is HN 3 = 0.5C1 = NF 3 , and our result is a factor of 2 too -4-American Institute of Aeronautics and Astronautics large. This is not a surprising result considering that Herbelin 24 and Henshaw 23 reported a very similar trend for AGIL 1. Their optimum F : HN 3 ratios for gain/lasing power were 2.3 and 1.9, respectively.…”
Section: Optimization Of Ncl(a'a)supporting
confidence: 54%
See 1 more Smart Citation
“…The Cl / HN 3 stoichiometry suggests that the optimum 28 condition for NCl(a'A) production is HN 3 = 0.5C1 = NF 3 , and our result is a factor of 2 too -4-American Institute of Aeronautics and Astronautics large. This is not a surprising result considering that Herbelin 24 and Henshaw 23 reported a very similar trend for AGIL 1. Their optimum F : HN 3 ratios for gain/lasing power were 2.3 and 1.9, respectively.…”
Section: Optimization Of Ncl(a'a)supporting
confidence: 54%
“…Indeed, a subsonic, continuous wave, chemical I*( 2 Pi/2> laser pumped by NCl(a'A) was reported by Henshaw and co-workers in 2000 23 . The authors named their discovery the All Gas-phase Iodine Laser, or AGIL.…”
Section: American Institute Of Aeronautics and Astronauticsmentioning
confidence: 95%
“…for example, produced a supersonic flow with T = 400 -500 K. According to temperaturedependent rate constant measurements and the previous subsonic AGIL work [1,24], this is nearly optimal for NCl(a A second challenge for future AGIL devices is tied to the laser fuel, HN 3 . Because of its potential (some would say propensity) for explosive decomposition, the storage and dynamic pressure of HN 3 must be kept low.…”
Section: Discussionmentioning
confidence: 99%
“…All reagent and diluent flow rates except for HN 3 were controlled by Proportion Air electronic gas pressure regulators (Model #QBIT-FEE-500) and calibrated sonic orifices. Table 1.…”
Section: Experimental Apparatusmentioning
confidence: 99%
See 1 more Smart Citation