2015 International Conference on Advances in Biomedical Engineering (ICABME) 2015
DOI: 10.1109/icabme.2015.7323258
|View full text |Cite
|
Sign up to set email alerts
|

A new energy detector of micro-emboli using a time-varying threshold

Abstract: International audienceDetection of small emboli, precursors of Cerebrovascular Accidents, is a worldwide concern since CVAs represent the second cause of mortality in the world. Computerized analysis of Transcranial Doppler signals can aid early detection of circulating emboli and micro-emboli. Commercially used systems of automatic emboli detection rely on standard short time Fourier transform techniques in which detection is based on constant thresholds. These standard algorithms do not offer robust detectio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
3
2

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(9 citation statements)
references
References 7 publications
(9 reference statements)
0
9
0
Order By: Relevance
“…The clinical study was approved by the ethical committee of the CHRU of Lille. The Holter Transcranial Doppler System-TCD-X (TCD-X, Atys Medical, Soucieu-en-Jarrest, France) along with the description of data collection can be found in our recently published articles [14,19].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The clinical study was approved by the ethical committee of the CHRU of Lille. The Holter Transcranial Doppler System-TCD-X (TCD-X, Atys Medical, Soucieu-en-Jarrest, France) along with the description of data collection can be found in our recently published articles [14,19].…”
Section: Methodsmentioning
confidence: 99%
“…The use of the TCD Holter version results in an increase in the number of signal artifacts. For this reason, a manual artifact rejection system was applied as in [14,19].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…To determine the detection threshold, we examine the standard deviation of prediction errors. (A similar strategy was previously proposed in [23].) In our method, the detection threshold is set to…”
Section: B Hits Detectionmentioning
confidence: 99%
“…Notice that instead of basing the detector on rapid change model, it is also possible to take into account heteroskedastic and cyclostationary properties in the energy random fluctuations [21,22]. In that case, the flucutation of the time-varying energy is obtained by removing the local trend (with a moving average process) from the energy Doppler signal (see Figure 3 (a)).…”
mentioning