2015
DOI: 10.1016/j.jaapos.2015.01.011
|View full text |Cite
|
Sign up to set email alerts
|

A new computer-based pediatric vision-screening test

Abstract: Background We developed and validated the Jaeb Visual Acuity Screener (JVAS), a computerized visual acuity-based screening program for children that employs a rapid, age-specific, standardized algorithm for vision screening in the medical home that is available for download at no cost. Methods A total of 175 children aged 3 to <8 (median, 6) years were screened with the JVAS before undergoing a complete eye examination (gold standard). The JVAS presented 2 large single surround optotypes (20/100 and 20/80) a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
12
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 13 publications
(12 citation statements)
references
References 18 publications
(26 reference statements)
0
12
0
Order By: Relevance
“…In children aged 5–6 years there was an enhanced advantage of TAO (AUC TAOregular = 0.97, AUC TAOvanishing = 0.98) over Parr (AUC Parr = 0.75). TAO results for sensitivity (TAO regular = 91%, TAO vanishing = 91%) and specificity (TAO regular = 85%, TAO vanishing = 82%) are in line with the electronic Jaeb Visual Acuity Screener, reporting optimal sensitivity and specificity of 90% and 83%, respectively . As with LoA, trials used within the QUEST protocol can be vastly truncated if screening is the goal.…”
Section: Discussionmentioning
confidence: 87%
“…In children aged 5–6 years there was an enhanced advantage of TAO (AUC TAOregular = 0.97, AUC TAOvanishing = 0.98) over Parr (AUC Parr = 0.75). TAO results for sensitivity (TAO regular = 91%, TAO vanishing = 91%) and specificity (TAO regular = 85%, TAO vanishing = 82%) are in line with the electronic Jaeb Visual Acuity Screener, reporting optimal sensitivity and specificity of 90% and 83%, respectively . As with LoA, trials used within the QUEST protocol can be vastly truncated if screening is the goal.…”
Section: Discussionmentioning
confidence: 87%
“…If the testing device could be integrated with the health‐care system, automation could also help with referral and follow‐up. Given their advantages, electronic acuity tests are being used more in community settings, and are increasingly recommended for a variety of applications including visual acuity measurements and screening . Disadvantages of such devices include the need for electricity and for specific testing environments to appropriately position the tablet, and reduce glare on the screen.…”
Section: Discussionmentioning
confidence: 99%
“…Newer technologies offer several advantages over traditional methods. First, many electronic tests can be run on the user's own equipment (for example the Jaeb Visual Acuity Screener can be run on any Microsoft Windows device), and can present targets (‘optotypes’) which are open‐access (freely available, for example the standard Sloan letters or The Auckland Optotypes [TAO]). Second, automation of the testing procedure can reduce scoring and recording errors, streamline data storage, promote referral and facilitate follow‐up.…”
mentioning
confidence: 99%
“…Some of these applications have been investigated through peer-reviewed publications. 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 The GoCheck Kids application is used for vision screening through photo-screening and checking visual acuity. This application has been studied for photoscreening and detecting amblyopia risk factors, but not for checking visual acuity.…”
Section: Introductionmentioning
confidence: 99%