A new clutter rejection algorithm for doppler ultrasound

Abstract: Several strategies, known as clutter or wall Doppler filtering, were proposed to remove the strong echoes produced by stationary or slow moving tissue structures from the Doppler blood flow signal. In this study, the matching pursuit (MP) method is proposed to remove clutter components. The MP method decomposes the Doppler signal into wavelet atoms that are selected in a decreasing energy order. Thus, the high-energy clutter components are extracted first. In the present study, the pulsatile Doppler signal s(n… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
29
0

Year Published

2004
2004
2017
2017

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 36 publications
(29 citation statements)
references
References 14 publications
0
29
0
Order By: Relevance
“…To explicitly examine the filtering difference form spectrogram, the low frequency part of above spectrograms was locally magnified and presented correspondingly in Fig.2. After the clutter component was removed, the S/C ratio can be calculated in terms of the equation (11) presented in literature [2]. The S/C ratio was 2.66 dB and 2.05 dB by the TIDWT with BSF and the HPF respectively, but the S/C ratio of the simulated contaminated signal was -20dB.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…To explicitly examine the filtering difference form spectrogram, the low frequency part of above spectrograms was locally magnified and presented correspondingly in Fig.2. After the clutter component was removed, the S/C ratio can be calculated in terms of the equation (11) presented in literature [2]. The S/C ratio was 2.66 dB and 2.05 dB by the TIDWT with BSF and the HPF respectively, but the S/C ratio of the simulated contaminated signal was -20dB.…”
Section: Resultsmentioning
confidence: 99%
“…The approaches applied to remove clutter are known as clutter or wall filter. The conventional methods used by ultrasound manufactures are mainly the static temporal finite and infinite impulse response high pass filters (HPF), and the standard linear regression filters (SLR) [1] [2]. Although the HPF is simple and effective for removing clutter components, there exists an obvious drawback that Doppler signals from the low blood flow falling into clutter frequency region are also simultaneously filtered out.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Stationary clutter rejection methods have been developed mostly for color Doppler flow imaging (Bjaerum et al, 2002;Cloutier et al, 2003;Yoo et al, 2003). For identifying reverberations in normal ultrasound images, Duarte et al (2003) presented an algorithm based on the comparison of power spectra and time-of-flight.…”
Section: Related Workmentioning
confidence: 99%
“…The vessel wall signals gravely obstruct the low-frequency blood flow signals, and make it difficult to extract blood flow signals close to the vessel wall exactly. In order to achieve intact blood flow signals, several researches have been proposed variety methods including eigen decomposition [3], blind signal separation [4], and recursive principal component analysis [5] in time domain, as well as matching pursuit [6], wavelet coefficient analysis [7] and short time Fourier transform [8] in frequency domain. Although the accuracy of the blood flow components extracted from the mixed signal has been improved in some extent by using these methods, the veracity and reliability of extraction can not be guaranteed due to the lack of an objective criterion for distinguishing the blood flow and vessel wall signals according to their different properties.…”
Section: Introductionmentioning
confidence: 99%