2013
DOI: 10.1063/1.4819589
|View full text |Cite
|
Sign up to set email alerts
|

A new calorimeter for the simultaneous calibration of SPRTs and CSPRTs at the triple point of mercury

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
4
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 0 publications
1
4
0
Order By: Relevance
“…To overcome the problem, LNE-Cnam built and characterized a new type of calorimeter for the calibration of both long-stem and capsule-type SPRTs at the mercury triple point. Measurements carried out with CSPRT 1041 in the new cell [9] are in agreement with the CCT-K2 measurements. This validates the hypothesis that the CCT-K2.4 measurements at the mercury triple point reported by LNE-Cnam were unreliable.…”
Section: Measurements Performed At Lne-cnamsupporting
confidence: 80%
“…To overcome the problem, LNE-Cnam built and characterized a new type of calorimeter for the calibration of both long-stem and capsule-type SPRTs at the mercury triple point. Measurements carried out with CSPRT 1041 in the new cell [9] are in agreement with the CCT-K2 measurements. This validates the hypothesis that the CCT-K2.4 measurements at the mercury triple point reported by LNE-Cnam were unreliable.…”
Section: Measurements Performed At Lne-cnamsupporting
confidence: 80%
“…W(T90) = R(T90) / R(273.16 K), where R are resistance values corrected for all the effects mentioned in Section 2. Both uMRA and ubest standard uncertainties are reported here directly in millikelvins with a coverage factor k = 1. dT/dW are the mean sensitivity values of the thermometer calculated at each fixed point from the W values, computed with the respective conversion software according to the deviation function (12) in [2], while dTij are the temperature differences between the two laboratories, computed as dTij = (dT/dW)•(Wi -Wj). Lastly, the degree of equivalence, d0.95, between the two NMIs is calculated on the basis of the expression [25]: Globally, ubest uncertainties are evaluated in the same way as uMRA.…”
Section: Resultsmentioning
confidence: 99%
“…In 2013, LNE-CNAM developed a calorimeter for the simultaneous calibration of long-stem and CSPRTs at the TP of Hg [12]. The difference with most traditional systems [11] is the capability to perform calorimetric realizations of the phase transition, as the apparatus is essentially an isothermal cryostat.…”
Section: Triple Point Of Hg and Associated Apparatusmentioning
confidence: 99%
See 2 more Smart Citations