A New Automated Computerized Analyzing System Simplifies Readings and Reduces the Variability in Ultrasound Measurement of Intima-Media Thickness

Abstract: The new automated analyzing system will not only greatly increase the speed of measurements but also reduce the variability between readers. It should also reduce the variability between different laboratories if the same analyzing program is used. Furthermore, the new system will probably prevent the problem with drift in measurements over time.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

6
282
4
13

Year Published

2005
2005
2020
2020

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 334 publications
(305 citation statements)
references
References 16 publications
6
282
4
13
Order By: Relevance
“…Following previously prescribed protocols, 25 these segments were imaged and measured by the same observer. The images were digitized and imported into the Artery Measurement Systems automated software 26,27 for dedicated analysis of intima-media thickness. A maximal 10-mm segment with good image quality was chosen for analysis.…”
Section: Cardiovascular Measurementsmentioning
confidence: 99%
“…Following previously prescribed protocols, 25 these segments were imaged and measured by the same observer. The images were digitized and imported into the Artery Measurement Systems automated software 26,27 for dedicated analysis of intima-media thickness. A maximal 10-mm segment with good image quality was chosen for analysis.…”
Section: Cardiovascular Measurementsmentioning
confidence: 99%
“…The images were digitized and imported into the AMS automated software for dedicated analyses of CIMT. 34,35 A maximal 10 mm segment with good image quality was chosen for analysis. The program automatically identifies the borders of the intima-media of the near and far wall, and the inner diameter of the vessel and calculates the CIMT and diameter from around 100 discrete measurements through the 10 mm segment.…”
Section: Measurements Of Sub-clinical Target Organ Damagementioning
confidence: 99%
“…Measurements were done in the far wall according to the leading edge principle using a specially designed, computer-assisted image analyzing system based on automated detection of the echo structures but with the option for manual corrections of the operator [23].…”
Section: Measurement Of Imtmentioning
confidence: 99%