A New Approach to Determining the Content and15N Abundance of Total Dissolved Nitrogen in Aqueous Samples: TOC Analyser-QMS Coupling

Abstract: The standard method for determining the 15N abundance of total dissolved nitrogen (TDN) in aqueous samples (e.g., soil leachate, sewage, urine) is currently Kjeldahl digestion followed by steam distillation or diffusion to isolate the ammonium, and then 15N measurement using IRMS. However, this technique is both time-consuming and laborious. One way of overcoming these disadvantages could be to couple a TOC analyser to determine the TDN with a sufficient quadrupole MS to determine the 15N abundance. The high T… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
10
0

Year Published

2003
2003
2018
2018

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 7 publications
0
10
0
Order By: Relevance
“…Hofmann et al 1997;Jung et al 1997;1999;Schulz et al 2001;Russow et al 2002). One possible application of stable isotopes like 15 N is their use as tracers in detecting the destiny of N-atoms, and on this basis, to determine the N-metabolism capacity of plant material (e.g.…”
Section: Genetic Analysis (Rapd-pcr)mentioning
confidence: 99%
“…Hofmann et al 1997;Jung et al 1997;1999;Schulz et al 2001;Russow et al 2002). One possible application of stable isotopes like 15 N is their use as tracers in detecting the destiny of N-atoms, and on this basis, to determine the N-metabolism capacity of plant material (e.g.…”
Section: Genetic Analysis (Rapd-pcr)mentioning
confidence: 99%
“…In general, it can be stated that the off‐line methods for TD 15 N are rather laborious for routine analyses. Russow et al 19. presented an on‐line measurement method for TD 15 N by using the coupling of a total organic carbon (TOC) analyser and a quadrupole mass spectrometer.…”
mentioning
confidence: 99%
“…1 in [1]), enabling CO 2 to be focused for a better peak shape for the subsequent QMS measurement (hereafter referred to as the cryo-focusing method). However, the very low O 2 content of the carrier gas also allows to feed the QMS directly with the carrier gas loaded with the sample's CO 2 (direct method).…”
mentioning
confidence: 99%
“…Therefore we investigated whether the TOC-QMS coupling previously described [1] is also suitable for measuring 13 C abundance. However, since the MS ESD 100 used is a quadrupole MS (QMS), the attainable precision is The equipment used consists of the HighTOC analyser (Elementar Analysensysteme Hanau, Germany) coupled to the QMS ESD 100 (InProcess Instruments Bremen, Germany) via a trap and flush interface (TFI), as described in detail in Russow et al [1]. The system uses a continuous flow method with He as the carrier gas containing 5% (vol.)…”
mentioning
confidence: 99%
See 1 more Smart Citation