A New Approach for Testing Fetal Heart Rate Monitors

Abstract: In this paper, a new approach for the periodical testing and the functionality evaluation of a fetal heart rate monitor device based on ultrasound principle is proposed. The design and realization of the device are presented, together with the description of its features and functioning tests. In the designed device, a relay element, driven by an electric signal that allows switching at two specific frequencies, is used to simulate the fetus and the mother’s heartbeat. The simulator was designed to be complian… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 29 publications
(28 reference statements)
0
2
0
Order By: Relevance
“…There are several studies that discuss fetal doppler including, in 2011 there were Lukas Zach, Vaclav Chud, Jakub Kuz, who discussed the appearance of FHR parameters on CTG using an android application [2] [16]. Heart rate although in this study there is a CTG [17][18] title but the researcher only sends and displays FHR, the researcher concludes that the use of the android application as a medium to display FHR data in the future can be used as a reference for the telemedicine system in monitoring FHR data, but this study has not discussed about lost data that exists when sending and receiving data.…”
Section: Introductionmentioning
confidence: 99%
“…There are several studies that discuss fetal doppler including, in 2011 there were Lukas Zach, Vaclav Chud, Jakub Kuz, who discussed the appearance of FHR parameters on CTG using an android application [2] [16]. Heart rate although in this study there is a CTG [17][18] title but the researcher only sends and displays FHR, the researcher concludes that the use of the android application as a medium to display FHR data in the future can be used as a reference for the telemedicine system in monitoring FHR data, but this study has not discussed about lost data that exists when sending and receiving data.…”
Section: Introductionmentioning
confidence: 99%
“…In Reference [ 5 ], the authors present a novel approach intended for the periodical testing of the function evaluation of fetal heart rate monitors. The proposed simulator was designed to be compliant with the standard requirements for the accurate assessment and measurement of medical devices.…”
mentioning
confidence: 99%