2010
DOI: 10.1111/j.1600-0846.2009.00412.x
|View full text |Cite
|
Sign up to set email alerts
|

A new approach for an estimation of the equilibrium stratum corneum water content

Abstract: The estimated water content is a bit lower than what can be expected to be realistic. A calibration against ambient RH is most probably needed if our method is to be applied over a broad range of values of the RH in the ambient air.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 21 publications
(25 reference statements)
0
5
0
Order By: Relevance
“…Because skin temperature influences water evaporation we statistically adjusted the TEWL to 30 C. Although a generally accepted conversion formula does not exist [44] the approach introduced by Mathias et al [35] was chosen, because it is the most established one in the literature [45,46]. After adjustment we still observed a substantial TEWL increase at the heels whereas the TEWL seemed not to change at the sacral skin.…”
Section: Discussionmentioning
confidence: 97%
“…Because skin temperature influences water evaporation we statistically adjusted the TEWL to 30 C. Although a generally accepted conversion formula does not exist [44] the approach introduced by Mathias et al [35] was chosen, because it is the most established one in the literature [45,46]. After adjustment we still observed a substantial TEWL increase at the heels whereas the TEWL seemed not to change at the sacral skin.…”
Section: Discussionmentioning
confidence: 97%
“…In the field of medical engineering, it is widely known that the low-frequency current mostly flows within the extracellular fluid, whereas the high-frequency current flows through intracellular and extracellular spaces; this property is found in all biological tissues. 28, 29, 30 In several functional studies, DIS has been recognized as a marker of impaired transepithelial permeability. 31, 32 Thus, when evaluating extracellular fluid volume, using a low-frequency current may be more useful to estimate DIS and transepithelial permeability.…”
Section: Discussionmentioning
confidence: 99%
“…, indicating that TEWL on the cheek decreased from the time point 0 h to 3 h, and significantly at 6 h ( P < 0.05), when the temperature was kept at 24–25°C with 10% relative humidity. TEWL is the amount of diffused water from the surface of SC, which depends on the water content of skin and ambient vapor . Water is continuously supplied from the deep layer of the skin toward the surface of SC to maintain the moisture level.…”
Section: Discussionmentioning
confidence: 99%