1976
DOI: 10.1080/00268977600102201
|View full text |Cite
|
Sign up to set email alerts
|

A neutron-diffraction study of liquid acetonitrile

Abstract: Neutron-diffraction studies on liquid deuterated acetonitrile at 20~C were carried out at neutron wavelengths of 0"5 A and 0.7 A.. For the latter wavelength samples of two different diameters were measured.The data were corrected for background, absorption, multiple scattering and inelastic effects (Placzek correction) and then were normalized to absolute differential cross section by comparison with vanadium standard. The different steps in the correction procedure were experimentally verified.The absolute co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

6
90
0

Year Published

1977
1977
2012
2012

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 165 publications
(96 citation statements)
references
References 28 publications
6
90
0
Order By: Relevance
“…The data were converted to an absolute scale by determining a normalization factor from a vanadium run. The details of the correction procedure are described elsewhere [12][13][14], X-ray diffraction measurements were carried out on flat plane-parallel specimens using transmission The details of the data processing and correction procedure are discussed in [15].…”
Section: Experimental and Data Evaluationmentioning
confidence: 99%
See 2 more Smart Citations
“…The data were converted to an absolute scale by determining a normalization factor from a vanadium run. The details of the correction procedure are described elsewhere [12][13][14], X-ray diffraction measurements were carried out on flat plane-parallel specimens using transmission The details of the data processing and correction procedure are discussed in [15].…”
Section: Experimental and Data Evaluationmentioning
confidence: 99%
“…where /nom\{k), /"elf (k), f*{k) are respectively the normalized coherent intensities, calculated self scattering of the atoms in one formamide molecule and tabulated [14][15][16][17] coherent scattering amplitudes for atoms /. Index a stands for the three different types of diffraction experiments.…”
Section: Experimental and Data Evaluationmentioning
confidence: 99%
See 1 more Smart Citation
“…The intensity for the empty furnace and a cadmium neutron-absorbing rod of similar diameter to the sample were also measured to account for the effect of sample self-shielding on the background count rate at small scattering angles. 17 Each complete diffraction pattern was built up from the intensities measured for the different detector groups. These intensities were saved at regular intervals and no deviation between them was observed, apart from the expected statistical variations, which verified the diffractometer and sample stability.…”
Section: Methodsmentioning
confidence: 99%
“…(6a) beyond q = q max is almost zero. Again, the function G d (r) is expected to be zero in the range 0 ≤ r ≤ r 0 where r 0 is about 1.5 Å because (Bertagnolli et al, 1976) for neutron data analysis of liquid acetonitrile.…”
Section: Modified Molecular Conformation Analysismentioning
confidence: 99%