A near-infrared C2H2/CH4 dual-gas sensor system combining off-axis integrated-cavity output spectroscopy and frequency-division-multiplexing-based wavelength modulation spectroscopy

Abstract: A near-infrared C2H2/CH4 sensor was demonstrated utilizing a miniaturized high finesse cavity with high sensitivity and remarkable dynamic measurement performance.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
12
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 31 publications
(12 citation statements)
references
References 35 publications
0
12
0
Order By: Relevance
“…When the averaging time reaches 700 s, increasing the averaging time cannot further improve the detection accuracy. At this time, the wavelength fluctuation noise is the main interference [30][31][32]. By further analysis of the test results we can find that the NH3 concentration detected in the corridor is about 50 ppm•m, which is a little higher than the normal NH3 concentration in air.…”
Section: System Stability and Allan Deviationmentioning
confidence: 83%
See 1 more Smart Citation
“…When the averaging time reaches 700 s, increasing the averaging time cannot further improve the detection accuracy. At this time, the wavelength fluctuation noise is the main interference [30][31][32]. By further analysis of the test results we can find that the NH3 concentration detected in the corridor is about 50 ppm•m, which is a little higher than the normal NH3 concentration in air.…”
Section: System Stability and Allan Deviationmentioning
confidence: 83%
“…When the averaging time reaches 700 s, increasing the averaging time cannot further improve the detection accuracy. At this time, the wavelength fluctuation noise is the main interfer ence [30][31][32].…”
Section: System Stability and Allan Deviationmentioning
confidence: 99%
“…Over the past decade, wavelength modulation spectroscopy (WMS) has been used in various applications as a widely accepted high-sensitivity detection technique [1], [2], [3]. It shifts to a high-frequency detection band by fast current modulation, suppressing the interference of 1/f noise.…”
Section: Introductionmentioning
confidence: 99%
“…Some harmful gases are toxic and flammable, e.g. acetylene (C 2 H 2 ) and methane (CH 4 ) [1][2][3], and they can even cause explosions when the concentration level exceeds the explosion limit. In order to avoid safety accidents, gas detection is particularly important.…”
Section: Introductionmentioning
confidence: 99%
“…The disadvantage of this cell is that the mirror utilization rate is low and the cell volume is too large. In 2019, Zheng et al proposed an acetylene sensor based on off-axis integrated-cavity output spectroscopy (OA-ICOS) [1]. The optical path length is greatly affected by the mirror reflectivity.…”
Section: Introductionmentioning
confidence: 99%