2020
DOI: 10.1039/c9ra09951d
|View full text |Cite
|
Sign up to set email alerts
|

A multifunctional ratiometric electrochemical sensor for combined determination of indole-3-acetic acid and salicylic acid

Abstract: For the first time, a multifunctional ratiometric electrochemical sensor was developed for quantifying IAA and SA simultaneously.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 23 publications
(10 citation statements)
references
References 39 publications
1
9
0
Order By: Relevance
“…3C and D, suggesting the sensitivity of the sensor can be improved by the double signal output greatly. Compared with some other electrochemical sensors of SA summarized in Table 1, 1,[31][32][33][34][35][36] although the LOD of our sensor was not lower than other sensors, the detection range of our sensor was wider than that of most sensors, and it can cover a large part of concentration range of SA in most plants, which is in the range of nM to mM. 37 More importantly, it is accurate, reliable and practical.…”
Section: Performance Of the Cu-mofs-cb-naon/spe Electrode For Detectmentioning
confidence: 84%
“…3C and D, suggesting the sensitivity of the sensor can be improved by the double signal output greatly. Compared with some other electrochemical sensors of SA summarized in Table 1, 1,[31][32][33][34][35][36] although the LOD of our sensor was not lower than other sensors, the detection range of our sensor was wider than that of most sensors, and it can cover a large part of concentration range of SA in most plants, which is in the range of nM to mM. 37 More importantly, it is accurate, reliable and practical.…”
Section: Performance Of the Cu-mofs-cb-naon/spe Electrode For Detectmentioning
confidence: 84%
“…However, the reproducibility of the electrode was demonstrated with an intra-electrode RSD of 0.7%, and an inter-electrode RSD of 5.0%, over five electrodes. Other modified CNTs include Fc labelling for the detection of nitrophenols [107], and phytohormones [108], and nitrogen-doped nanosheets for the detection of metal ions [109]. Carbon nanotubes were also integral to the detection of heavy metal ions by Shen et al [110].…”
Section: (B) Metal Organic Frameworkmentioning
confidence: 99%
“…Indole-3-acetic acid (IAA) and salicylic acid (SA) are the two most typical electroactive phytohormones. In recent years, electrochemical sensors based on carbon materials (multiwalled carbon nanotubes (MWCNTs)–chitosan [ 12 ], carboxymethyl cellulose–montmorillonite single walled carbon nanotube [ 13 ], graphene oxide-modified carbon tape [ 14 ], gold nanoparticles-doped graphene hydrogel nanocomposites [ 15 ], graphene hydrogel [ 16 ], MWCNTs–carbon black composites [ 13 ], and carbon cement [ 17 ]) for IAA and SA detection have been reported. However, developing an effective method for sensitive simultaneous detection of phytohormones remains a challenge.…”
Section: Introductionmentioning