2013
DOI: 10.1016/j.jaerosci.2013.02.006
|View full text |Cite
|
Sign up to set email alerts
|

A multi-wavelength optical set-up for the characterization of carbonaceous particulate matter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
45
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 41 publications
(46 citation statements)
references
References 39 publications
1
45
0
Order By: Relevance
“…This instrument was developed by Massabò et al (2013) and measures the light transmitted through a filter sample (forward hemisphere) and the light reflected at two different angles (backward hemisphere) in a similar configuration to the MAAP. By using a radiative transfer model, the light absorption coefficients can be calculated.…”
Section: Instrumentationmentioning
confidence: 99%
See 1 more Smart Citation
“…This instrument was developed by Massabò et al (2013) and measures the light transmitted through a filter sample (forward hemisphere) and the light reflected at two different angles (backward hemisphere) in a similar configuration to the MAAP. By using a radiative transfer model, the light absorption coefficients can be calculated.…”
Section: Instrumentationmentioning
confidence: 99%
“…In this study, we use a multi-wavelength absorbance analyzer (MWAA), introduced by Massabò et al (2013Massabò et al ( , 2015, to conduct a systematic multi-wavelength evaluation of ambient data. This way we can estimate the impact of the most common and reliable Aethalometer correction schemes on the å ABS uncertainties.…”
mentioning
confidence: 99%
“…Optical transmittance measurements are sometimes added to PTFE measurement suites as a proxy determination for "black carbon" (Cahill et al 1984;Nejedly et al 2003;Cuccia et al 2010;Barraza-Villarreal et al 2011) and, with sufficient spectral resolution, environmental tobacco smoke (Lawless et al 2004;Yan et al 2011). Massabo et al (2013) recently developed a multi-wavelength and multiangle optical system to make off-line MAAP-like absorption measurements on PTFE as well as quartz fiber filters.…”
Section: Ptfe Filters and The Improve Networkmentioning
confidence: 99%
“…The sample presents less optical depth to normally incident than to diffuse irradiance, reflecting a fraction R C R of this collimated beam. The backscattered radiance is approximately diffuse (Massabo et al 2013;Vecchi et al 2014), reflecting the random microstructure of the expanded PTFE membrane. The backscattered laser flux accordingly provides approximately uniform irradiance of the sphere's interior, with a total incident power of about P 0 D h S R C F laser .…”
Section: ¡1mentioning
confidence: 99%
See 1 more Smart Citation