2019
DOI: 10.1109/tnsre.2019.2937000
|View full text |Cite
|
Sign up to set email alerts
|

A Multi-Mode Rehabilitation Robot With Magnetorheological Actuators Based on Human Motion Intention Estimation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
41
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
10

Relationship

2
8

Authors

Journals

citations
Cited by 54 publications
(42 citation statements)
references
References 26 publications
0
41
0
Order By: Relevance
“…Whereas in the human-active mode, the human leg dominantly guides the movement of the robotic exoskeleton, and the MR actuator functions as a brake to help the user conduct anti-resistance training to strengthen muscles. Switching between these modes is allowed based on the user’s motion intention (Xu et al , 2019c, 2019a). In this mirror therapy framework, the MR actuators set at the leader robot work in the human-active mode and the MR actuators equipped at the follower exoskeleton are tuned to the robot-active mode.…”
Section: Methodsmentioning
confidence: 99%
“…Whereas in the human-active mode, the human leg dominantly guides the movement of the robotic exoskeleton, and the MR actuator functions as a brake to help the user conduct anti-resistance training to strengthen muscles. Switching between these modes is allowed based on the user’s motion intention (Xu et al , 2019c, 2019a). In this mirror therapy framework, the MR actuators set at the leader robot work in the human-active mode and the MR actuators equipped at the follower exoskeleton are tuned to the robot-active mode.…”
Section: Methodsmentioning
confidence: 99%
“…The MRB model is developed by following the behaviour trend of MRB that is gathered through experiment. The MR brake actuator model is developed based on the characteristics of the MR brake, where the brake torque increases proportionally with apply current and independent speed [30], [31], [32]. In this model, the actuator is designed based on rotational wheel speed, and it is assumed that the torque remains the same at all speed.…”
Section: Hardware and Testing Apparatusmentioning
confidence: 99%
“…where N is the number of the MR fluid working gaps, and R 1 and R 2 are the effective inner and outer radii of the working gap, respectively. The electromagnetic simulation of the MR actuator is conducted to verify the rationality of the structural design (Xu et al, 2019). The material properties of each component are assigned.…”
Section: Magnetorheological Actuatormentioning
confidence: 99%